Usefulness of sonographic guidance during percutaneous biopsy of mesenteric masses.

Ho Lisa M, Thomas John, Fine Stephen A, Paulson Erik K

Оценочное исследованиеСтатьяПеревод в очереди

Аннотация

OBJECTIVE

The objective of our study was to determine the usefulness of sonographic guidance for biopsy of mesenteric masses.

MATERIALS AND

METHODS

Twenty-five sonographically guided percutaneous biopsies of mesenteric masses were performed in 23 patients. Biopsies were performed with an 18-, 20-, or 22-gauge self-aspirating needle or core biopsy device. Final pathology results and patient medical records were reviewed for biopsy accuracy and complications. A biopsy was considered successful if a specific benign or malignant diagnosis was rendered by the pathologist or if surgical-pathologic confirmation was obtained.

RESULTS

Open surgical biopsy was performed after sonographically guided biopsy in 13 patients and led to 12 concordant diagnoses (nine true-positives and three true-negatives) and one discordant diagnosis (false-negative). Specific pathologic diagnosis was rendered for the 10 percutaneous biopsies that were not confirmed by surgical biopsy: five biopsies matched known primary malignancies, consistent with metastases; four biopsies revealed primary tumors, and one biopsy revealed chronic inflammation (nine true-positives and one true-negative). Two biopsies were nondiagnostic because of insufficient material (n = 1) and necrotic tumor (n = 1). In the biopsies with diagnostic tissue specimens, sonographically guided biopsy achieved a sensitivity of 95% (18/19) and specificity of 100% (4/4) for allowing neoplastic tissue to be distinguished from nonneoplastic tissue. Complications included a mesenteric hematoma and abdominal wall cellulitis.

CONCLUSION

Percutaneous biopsy of mesenteric masses is a useful and safe procedure.

Для цитирования: Ho Lisa M, Thomas John, Fine Stephen A, Paulson Erik K. Usefulness of sonographic guidance during percutaneous biopsy of mesenteric masses.. AJR. American journal of roentgenology. 2003. DOI: 10.2214/ajr.180.6.1801563.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.