Pulmonary vein ostium shape and orientation as possible predictors of occlusion in patients with drug-refractory paroxysmal atrial fibrillation undergoing cryoballoon ablation.

Sorgente Antonio, Chierchia Gian Battista, de Asmundis Carlo, Sarkozy Andrea, Namdar Mehdi, Capulzini Lucio, Yazaki Yoshinao, Müller-Burri Stephan-Andreas, Bayrak Fatih, Brugada Pedro

СтатьяПеревод пока не подготовлен

Аннотация

AIMS: No specific data are available on the influence of pulmonary vein (PV) anatomy and shape on cryoballoon ablation (CA) catheter efficacy in delivering cryothermal energy and, consequently, in obtaining PV isolation.

METHODS AND

RESULTS

Among a larger series of patients (68) with drug-refractory paroxysmal atrial fibrillation who underwent CA in our department, 52 patients were included in our study. All of them had a multislice cardiac computed tomography (MSCT) before the procedure. We retrospectively evaluated their MSCT scans focusing our attention on PV ovality and orientation in the frontal plane. A fair inverse association was documented between the ovality index of the left PVs and the degree of occlusion (r=-0.486 and P<0.003 for the LSPV and r=-0.360 and P=0.033 for the LIPV), whereas no association was found between the ovality index of the right PVs and the degree of occlusion (r=-0.283 and P=0.083 for the RSPV and r=0.235 and P=0.093 for RIPV). Nevertheless, a strong inverse association was found between the orientation of the PV ostia and the degree of occlusion in each vein (r=-0.804 and P<0.001 for the LSPV, r=-0.415 and P=0.013 for LIPV, r=-0.798 and P<0.001 for the RSPV, and r=-0.867 and P<0.001 for RIPV).

CONCLUSION

Pulmonary vein ostium shape and orientation evaluated by MSCT proved to be useful in predicting the degree of occlusion obtained during CA.

Для цитирования: Sorgente Antonio, Chierchia Gian Battista, de Asmundis Carlo, Sarkozy Andrea, Namdar Mehdi, Capulzini Lucio, Yazaki Yoshinao, Müller-Burri Stephan-Andreas, Bayrak Fatih, Brugada Pedro. Pulmonary vein ostium shape and orientation as possible predictors of occlusion in patients with drug-refractory paroxysmal atrial fibrillation undergoing cryoballoon ablation.. Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology. 2010. DOI: 10.1093/europace/euq388.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.