m+Medelevator.RU
← Поиск публикаций
Circulation. Arrhythmia and electrophysiology · 2010

Safety and efficacy of pulmonary vein antral isolation in patients with obstructive sleep apnea: the impact of continuous positive airway pressure.

Сравнительное исследованиеСтатьяМногоцентровое исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Patel Dimpi, Mohanty Prasant, Di Biase Luigi, Shaheen Mazen, Lewis William R, Quan Kara, Cummings Jennifer E, Wang Paul, Al-Ahmad Amin, Venkatraman Preeti, Nashawati Eyad, Lakkireddy Dhanunjaya, Schweikert Robert, Horton Rodney, Sanchez Javier, Gallinghouse Joseph, Hao Steven, Beheiry Salwa, Cardinal Deb S, Zagrodzky Jason, Canby Robert, Bailey Shane, Burkhardt J David, Natale Andrea

Аннотация

BACKGROUND: Obstructive sleep apnea (OSA) may be associated with pulmonary vein antrum isolation (PVAI) failure. The aim of the present study was to investigate if treatment with continuous positive airway pressure (CPAP) improved PVAI success rates.

METHODS AND RESULTS: From January 2004 to December 2007, 3000 consecutive patients underwent PVAI. Patients were screened for OSA and CPAP use. Six hundred forty (21.3%) patients had OSA. Patients with OSA had more procedural failures (P=0.024) and hematomas (P<0.001). Eight percent of the non-OSA paroxysmal atrial fibrillation patients had nonpulmonary vein antrum triggers (non-PV triggers) and posterior wall firing versus 20% of the OSA group (P<0.001). Nineteen percent of the non-OSA nonparoxysmal atrial fibrillation population had non-PV triggers versus 31% in the OSA group (P=0.001). At the end of the follow-up period (32±14 months), 79% of the non-CPAP and 68% of the CPAP group were free of atrial fibrillation (P=0.003). Not using CPAP in addition to having non-PV triggers strongly predicted procedural failure (hazard ratio, 8.81; P<0.001).

CONCLUSIONS: OSA was an independent predictor for PVAI failure. Treatment with CPAP improved PVAI success rates. Patients not treated with CPAP in addition to having higher prevalence of non-PV triggers were 8 times more likely to fail the procedure.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты