Evaluation of left atrial function by multidetector computed tomography before left atrial radiofrequency-catheter ablation: comparison of a manual and automated 3D volume segmentation method.

Wolf Florian, Ourednicek Petr, Loewe Christian, Richter Bernhard, Gössinger Heinz David, Gwechenberger Marianne, Plank Christina, Schernthaner Rüdiger Egbert, Toepker Michael, Lammer Johannes, Feuchtner Gudrun M

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

INTRODUCTION

The purpose of this study was to compare a manual and automated 3D volume segmentation tool for evaluation of left atrial (LA) function by 64-slice multidetector-CT (MDCT).

METHODS AND MATERIALS: In 33 patients with paroxysmal atrial fibrillation a MDCT scan was performed before radiofrequency-catheter ablation. Atrial function (minimal volume (LAmin), maximal volume (LAmax), stroke volume (SV), ejection fraction (EF)) was evaluated by two readers using a manual and an automatic tool and measurement time was evaluated.

RESULTS

Automated LA volume segmentation failed in one patient due to low LA enhancement (103HU). Mean LAmax, LAmin, SV and EF were 127.7 ml, 93 ml, 34.7 ml, 27.1% by the automated, and 122.7 ml, 89.9 ml, 32.8 ml, 26.3% by the manual method with no significant difference (p>0.05) and high Pearsons correlation coefficients (r=0.94, r=0.94, r=0.82 and r=0.85, p<0.0001), respectively. The automated method was significantly faster (p<0.001). Interobserver variability was low for both methods with Pearson's correlation coefficients between 0.98 and 0.99 (p<0.0001).

CONCLUSIONS

Evaluation of LA volume and function with 64-slice MDCT is feasible with a very low interobserver variability. The automatic method is as accurate as the manual method but significantly less time consuming permitting a routine use in clinical practice before RF-catheter ablation.

Для цитирования: Wolf Florian, Ourednicek Petr, Loewe Christian, Richter Bernhard, Gössinger Heinz David, Gwechenberger Marianne, Plank Christina, Schernthaner Rüdiger Egbert, Toepker Michael, Lammer Johannes, Feuchtner Gudrun M. Evaluation of left atrial function by multidetector computed tomography before left atrial radiofrequency-catheter ablation: comparison of a manual and automated 3D volume segmentation method.. European journal of radiology. 2010. DOI: 10.1016/j.ejrad.2010.03.020.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.