Long-term clinical outcome following pulmonary vein isolation with high-intensity focused ultrasound balloon catheters in patients with paroxysmal atrial fibrillation.

Metzner Andreas, Chun K R Julian, Neven Kars, Fuernkranz Alexander, Ouyang Feifan, Antz Matthias, Tilz Roland, Zerm Thomas, Koektuerk Buelent, Wissner Eric, Koester Ilka, Ernst Sabine, Boczor Sigrid, Kuck Karl-Heinz, Schmidt Boris

СтатьяПеревод пока не подготовлен

Аннотация

AIMS: High-intensity focused ultrasound (HIFU) applied via a balloon catheter is a novel technology for pulmonary vein isolation (PVI) in patients with paroxysmal atrial fibrillation (PAF). The long-term success rate is unknown.

METHODS AND

RESULTS

Thirty-two patients (22 male, age 60 +/- 9 years) with a long history [5 (4;9) years] of drug refractory [3 +/- 1 anti-arrhythmic drugs (AADs)], symptomatic PAF were included into the analysis. Pulmonary vein isolation was performed using the first- and second-generation HIFU balloon catheters (ProRhythm, Ronkonkoma, NY, USA). Follow-up (F/U) included regular telephonic interviews, trans-telephonic Holter ECG, and event recording. Recurrence was defined as a documented or symptomatic AF episode >30 s without a blanking period. In total 101/116 targeted PVs (87%) were acutely isolated exclusively using HIFU. During a median F/U of 1400 (930;1568) days, 18 patients (56%) were free of AF without AAD after a single HIFU procedure. In nine patients with AF recurrence, 20 PVs exhibited electrical reconduction and re-isolation was performed using irrigated radiofrequency current (RFC) ablation.

CONCLUSION

Patients treated with the first- and second-generation HIFU balloon catheters due to symptomatic PAF show long-term success rates similar to RFC-based PVI procedures. The major determinant of AF recurrence after HIFU treatment seems to be reconduction of previously isolated PVs. However, the favourable effectiveness is offset by the severe complications reported following HIFU treatment. This led to a halt of its clinical use.

Для цитирования: Metzner Andreas, Chun K R Julian, Neven Kars, Fuernkranz Alexander, Ouyang Feifan, Antz Matthias, Tilz Roland, Zerm Thomas, Koektuerk Buelent, Wissner Eric, Koester Ilka, Ernst Sabine, Boczor Sigrid, Kuck Karl-Heinz, Schmidt Boris. Long-term clinical outcome following pulmonary vein isolation with high-intensity focused ultrasound balloon catheters in patients with paroxysmal atrial fibrillation.. Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology. 2010. DOI: 10.1093/europace/eup416.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.