MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/j.1540-8167.2009.01592.x

Медицинская библиотека · Journal of cardiovascular electrophysiology · 2009

Reduced fluoroscopy during atrial fibrillation ablation: benefits of robotic guided navigation.

Steven Daniel, Servatius Helge, Rostock Thomas, Hoffmann Boris, Drewitz Imke, Müllerleile Kai, Sultan Arian, Aydin Muhammet Ali, Meinertz Thomas, Willems Stephan

СтатьяРандомизированное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

Recently, a nonmagnetic robotic navigation system (RN, Hansen-Sensei) has been introduced for remote catheter manipulation.

OBJECTIVE

To investigate the influence of RN combined with intuitive 3-dimensional mapping on the fluoroscopy exposure to operator and patient during pulmonary vein isolation (PVI) for paroxysmal atrial fibrillation (PAF) in a prospective randomized trial.

METHODS

Sixty patients were randomly assigned to undergo PVI either using a RN guided (group 1; n = 30, 20 male, 62 +/- 7.7 years) or conventional ablation approach (group 2; n = 30, 14 male, 61 +/- 7.6 years). A 3-dimensional mapping system (NavX) was used in both groups.

RESULTS

Electrical disconnection of the ipsilateral pulmonary veins (PVs) was achieved in all patients. Use of RN significantly lowered the overall fluoroscopy time (9 +/- 3.4 vs 22 +/- 6.5 minutes; P < 0.001) and reduced the operator's fluoroscopy exposure (7 +/- 2.1 vs 22 +/- 6.5 minutes; P < 0.001). The difference in fluoroscopy duration between both groups was most pronounced during the ablation part of the procedure (3 +/- 2.4 vs 17 +/- 6.3 minutes; P < 0.001). The overall procedure duration tended to be prolonged using RN without reaching statistical significance (156 +/- 44.4 vs 134 +/- 12 minutes, P = 0.099). No difference regarding outcome was found during a midterm follow-up of 6 months (AF freedom group 1 = 73% vs 77% in group 2 [P = 0.345]).

CONCLUSION

The use of RN for PVI seems to be effective and significantly reduces overall fluoroscopy time and operator's fluoroscopy exposure without affecting mid-term outcome after 6-month follow-up.

Для цитирования: Steven Daniel, Servatius Helge, Rostock Thomas, Hoffmann Boris, Drewitz Imke, Müllerleile Kai, Sultan Arian, Aydin Muhammet Ali, Meinertz Thomas, Willems Stephan. Reduced fluoroscopy during atrial fibrillation ablation: benefits of robotic guided navigation.. Journal of cardiovascular electrophysiology. 2009. DOI: 10.1111/j.1540-8167.2009.01592.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.