m+Medelevator.RU
← Поиск публикаций
Journal of cardiovascular electrophysiology · 2009

Pressure-guided cryoballoon isolation of the pulmonary veins for the treatment of paroxysmal atrial fibrillation.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Siklódy Claudia Herrera, Minners Jan, Allgeier Martin, Allgeier Hans-Jürgen, Jander Nikolaus, Keyl Cornelius, Weber Reinhold, Schiebeling-Römer Jochen, Kalusche Dietrich, Arentz Thomas

Аннотация

BACKGROUND: Pulmonary vein (PV) isolation using a balloon-mounted cryoablation system is a new technology for the percutaneous treatment of atrial fibrillation (AF). Complete PV occlusion during balloon ablation has been shown to predict successful electrical isolation. The aim of this study was to correlate mechanical PV occlusion with changes in a pressure curve recorded at the distal tip of the cryoballoon catheter.

METHODS AND RESULTS: We analyzed 51 PVs in 12 patients (61 +/- 6 years old) with paroxysmal AF. At first, PV occlusion via the cryoballoon was documented by changes in the pressure curve. Once the PV is occluded, the pressure curve registered in the vein converts from a left atrial pressure curve to a pulmonary artery pressure curve: the PV wedge curve. Occlusion was then confirmed by transesophageal echocardiography (TEE). Following 2 cryoablation applications, electrical PV isolation was assessed with a circumferential mapping catheter. Under the exclusive guidance of changes in the pressure curve at the tip of the cryoballoon, mechanical occlusion confirmed by TEE was achieved in 47 of 51 PVs (92%). Three PVs required further TEE guidance to achieve occlusion. All 50 occluded veins were electrically isolated after cryoablation. One right inferior vein, which could not be occluded with the balloon, displayed conduction post cryoablation and was isolated by focal ablation.

CONCLUSIONS: Occlusion and electrical isolation of PVs during cryoballoon ablation can be predicted by the appearance of a PV wedge curve at the tip of the catheter. This new straightforward parameter may facilitate the procedure.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты