PURPOSE: The purpose of this study is to identify the electrophysiological factors affecting symptoms in paroxysmal atrial fibrillation (PAF) using patients with paroxysmal atrial fibrillation and pacemakers with advanced atrial fibrillation (AF) diagnostics.

METHODS

Seventy-nine patients (age 71.0 +/- 8.2, 54.4% male) with symptomatic PAF and AF burden of 1% to 50% with DDDRP pacemakers implanted were assessed for 6 months. Patients recorded symptom onset and duration and these were correlated with device-derived electrophysiological data.

RESULTS

Of 2,638 AF episodes, 333 were symptomatic and 2,305 asymptomatic, with 194 non-atrial tachyarrhythmia symptomatic episodes giving a sensitivity of 12.6% and a positive predictive value of 63.2% for specific AF symptoms. Symptomatic AF episodes were 3.8 times more common diurnally than nocturnally (p < 0.001). Diurnally, symptomatic AF was significantly associated with a shorter AF cycle length (CL; p = 0.04), faster ventricular rate (p = 0.004), shorter PR interval (p < 0.001), faster preceding heart rate (p = 0.001) and increased early recurrence of AF (p < 0.04). Nocturnally, a significantly longer AF CL (p = 0.04) and PR interval (p < 0.001) prior to AF onset predicted symptomatic AF.

CONCLUSIONS

Symptoms in PAF are predicted by changes in AF episode duration, ventricular rate during AF, preceding sinus heart rate, AV nodal conduction and AF cycle length but not ventricular irregularity. Excess diurnal sympathetic tone and excess nocturnal vagal tone predispose to symptomatic PAF. These findings may have relevance for therapies for symptom control of PAF.

Для цитирования: Silberbauer John, Veasey Rick A, Cheek Elizabeth, Maddekar Nadeem, Sulke Neil. Electrophysiological characteristics associated with symptoms in pacemaker patients with paroxysmal atrial fibrillation.. Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing. 2009. DOI: 10.1007/s10840-009-9411-x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.