Quantitative assessment of cibenzoline administration for vagally mediated paroxysmal atrial fibrillation using frequency-domain heart rate variability analysis.

Miyakoshi Mutsumi, Ikeda Takanori, Miwa Yosuke, Sakaki Katsura, Ishiguro Haruhisa, Abe Atsuko, Tsukada Takehiro, Mera Hisaaki, Yusu Satoru, Yoshino Hideaki

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Cibenzoline (CBZ), a class I antiarrhythmic drug, has been widely used to maintain sinus rhythm in patients with paroxysmal atrial fibrillation (P-AF). This agent has an anticholinergic action and will become the drug of first choice for vagally mediated P-AF. We assessed its efficacy quantitatively by analyzing the frequency-domain heart rate variability (FD-HRV) of the Holter electrocardiogram (ECG) in patients with vagal P-AF.

METHODS

We enrolled 65 consecutive patients with vagal P-AF, but 31 patients were excluded because of the occurrence of significant arrhythmias during the 24-h Holter recordings. Accordingly, CBZ was administered to the remaining 34 patients. After administration, a Holter ECG recording was made again. High frequency (HF) components, i.e., vagal tone index, on the FD-HRV analysis from 00:00 h to 06:00 h were used for assessment. In 14 patients, the treatment was changed to disopyramide (DSP) and the same analyses were performed.

RESULTS

In two patients, the FD-HRV analysis was not utilized after administration. Finally, 32 patients were available for evaluation. CBZ was considered effective for vagal P-AF in 24 patients (75%). After administration, the HF component levels decreased (1589+/-795 ms(2) vs. 850+/-524 ms(2), p<0.0001). Comparison of the pre-administration HF component levels between the CBZ-responsive group and the CBZ-non-responsive group showed higher levels in the CBZ-responsive group (1766+/-758 ms(2) vs. 1058+/-690 ms(2), p=0.026). Although no significant difference in the reduction of the HF component levels was found between CBZ and DSP, DSP had anticholinergic side effects in two patients (14%).

CONCLUSIONS

In vagal P-AF patients, larger HF components on the FD-HRV analysis could be a hallmark of the antiarrhythmic action of CBZ. The reduction in the HF component levels after drug administration is useful for a quantitative assessment of anticholinergic action.

Для цитирования: Miyakoshi Mutsumi, Ikeda Takanori, Miwa Yosuke, Sakaki Katsura, Ishiguro Haruhisa, Abe Atsuko, Tsukada Takehiro, Mera Hisaaki, Yusu Satoru, Yoshino Hideaki. Quantitative assessment of cibenzoline administration for vagally mediated paroxysmal atrial fibrillation using frequency-domain heart rate variability analysis.. Journal of cardiology. 2009. DOI: 10.1016/j.jjcc.2009.04.009.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.