MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/j.1540-8159.2008.02277.x

Медицинская библиотека · Pacing and clinical electrophysiology : PACE · 2009

Early experience with robotic navigation for catheter ablation of paroxysmal atrial fibrillation.

Kautzner Josef, Peichl Petr, Cihák Robert, Wichterle Dan, Mlcochová Hanka

Контролируемое клиническое исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

INTRODUCTION

Pulmonary venous antra isolation (PVAI) is the cornerstone of catheter ablation procedure for drug refractory paroxysmal atrial fibrillation (AF). However, the procedure is technically challenging. Robotic navigation has a potential to expedite and facilitate the procedure.

METHODS

A robotic catheter control system was used for remote navigation-supported PVAI in 22 patients (mean age = 55 +/- 9 years, 16 males, study group). An irrigated-tip catheter with estimate of catheter force on the tissue was used. This was compared in nonrandomized fashion with conventional hand-controlled catheter ablation in 16 patients (mean age = 55 +/- 9 years, 13 males, control group). The procedures were performed under guidance of Ensite NavX navigation system (St. Jude Medical, St. Paul, MN, USA) and intracardiac echocardiography.

RESULTS

Robotic navigation was associated with significantly shorter overall duration of radiofrequency delivery (1,641 +/- 609 vs 2,188 +/- 865 seconds, P < 0.01), shorter total procedural time (207 +/- 29 vs 250 +/- 62 minutes, P = 0.007), fluoroscopy exposure (15 +/- 5 vs 27 +/- 9 minutes, P < 0.001), and lower radiation dose (1,119 +/- 596 vs 3,048 +/- 2,029 mGy/m(2), P < 0.001). No complication was observed in either the study or the control group. During the 5 +/- 1 months follow-up in the study group and 9 +/- 3 months in the control group, 91% and 81% of patients, respectively, were AF free.

CONCLUSIONS

In our early clinical experience, PVAI using a remote robotic catheter navigation was effective, safe, and associated with shorter procedural and fluoroscopic times than conventional PVAI.

Для цитирования: Kautzner Josef, Peichl Petr, Cihák Robert, Wichterle Dan, Mlcochová Hanka. Early experience with robotic navigation for catheter ablation of paroxysmal atrial fibrillation.. Pacing and clinical electrophysiology : PACE. 2009. DOI: 10.1111/j.1540-8159.2008.02277.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.