MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10840-008-9340-0

Медицинская библиотека · Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing · 2009

Radiofrequency ablation of paroxysmal atrial fibrillation by mesh catheter.

Pratola Claudio, Notarstefano Pasquale, Artale Paolo, Toselli Tiziano, Baldo Elisa, Marcantoni Lina, Carrescia Chiara, Squasi Paolo, Ferrari Roberto

Клиническое исследованиеСтатьяПеревод пока не подготовлен

Аннотация

INTRODUCTION

Pulmonary veins isolation usually requires a multielectrode catheter for mapping in addition to the ablation catheter. We describe our experience with a new multipolar catheter designed for simultaneous mapping and ablation (MESH, Bard).

METHODS AND

RESULTS

We tested the catheter in 15 patients (mean age 61.1 +/- 7.9; eight men) scheduled for paroxysmal atrial fibrillation ablation. The catheter was positioned in front of the pulmonary vein ostia. A pulmonary vein potential was demonstrated in 63.5% of the veins, which were disconnected with a mean of 1.6 radiofrequency applications with a mean time of 351 +/- 125.8 s (range 180-650) for each vein. Mean procedural time was 93 +/- 17.1 min (range 65-120), and fluoroscopy time was 13.7 +/- 4.0 (range 5-15) min. No complications occurred during and after or procedures.

CONCLUSION

Pulmonary veins disconnection with MESH ablator catheter is feasible with short procedural and X-ray exposure time. Further studies are needed to compare this new device to standard multipolar mapping catheters in order to evaluate its ability to correctly identify pulmonary vein potentials and to compare its safety and efficacy.

Для цитирования: Pratola Claudio, Notarstefano Pasquale, Artale Paolo, Toselli Tiziano, Baldo Elisa, Marcantoni Lina, Carrescia Chiara, Squasi Paolo, Ferrari Roberto. Radiofrequency ablation of paroxysmal atrial fibrillation by mesh catheter.. Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing. 2009. DOI: 10.1007/s10840-008-9340-0.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.