Subtraction helical CT angiography of intra- and extracranial vessels: technical considerations and preliminary experience.

Jayakrishnan Vijayam K, White Philip M, Aitken Douglas, Crane Paul, McMahon Alex D, Teasdale Evelyn M

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND AND PURPOSE: Reported CT angiographic (CTA) subtraction methods are not simple, robust, or real time. We investigated a novel technique for semiautomated digital subtraction CTA of the intracranial and extracranial arteries.

METHODS

Thirty patients underwent precontrast (low milliampere-seconds) and postcontrast (pitch, 1.5; collimation, 1-2.5 mm) helical imaging with a vacuum-type head holder to facilitate image registration and minimize movement. A reconstructed three-dimensional model of the precontrast bone dataset was subtracted from the postcontrast dataset to produce subtracted maximum-intensity-projection angiograms. Experienced (operator 1) and less-experienced (operator 2) staff performed the standard and subtraction reconstructions, and image generation time and quality (graded 1-5) were compared. A third operator blinded to the method assessed the hard-copy image quality.

RESULTS

Image quality with subtraction postprocessing was significantly better with both operators (operator 1, mean improvement of 0.87 grade, median improvement of 1 grade, P <.001; operator 2, mean improvement of 0.63 grade, median improvement of 1 grade, P <.001). Hard-copy image quality was better with the subtraction method (operator 1, P >.001; operator 2, P <.001). Blood vessels at the base of the brain were better demonstrated on subtraction images in 13 of 14 examinations. For the less experienced operator, the reconstruction time was significantly less with the subtraction method than with the conventional method (mean, 7.5 vs 10.1 minutes; P =.001).

CONCLUSION

When separation of the vasculature from bone is important and technically difficult, digital subtraction CTA offers a potential advantage. This semiautomated technique is fast and easy to learn, and variably experienced staff can use it.

Для цитирования: Jayakrishnan Vijayam K, White Philip M, Aitken Douglas, Crane Paul, McMahon Alex D, Teasdale Evelyn M. Subtraction helical CT angiography of intra- and extracranial vessels: technical considerations and preliminary experience.. AJNR. American journal of neuroradiology. 2003.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.