Metacarpal Lengthening Using a Mini-Ring Ilizarov Device for Thumb Reconstruction.

Zhu Yueliang, Xu Yongqing, Pu Shaoquan, Lv Qian, Cai Xingbo, Zhao Yonghui

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To explore the results of using the mini-ring Ilizarov external fixator for thumb metacarpal lengthening and its compatibility with a simultaneous groin flap.

METHODS

From May 2016 to June 2019, 17 adult patients with thumb loss were treated with metacarpal lengthening using a mini-ring Ilizarov device. The device was composed of 2 rings, threaded rods, nuts, and K-wires (diameter, 1.5 mm). Of these patients, 6 also underwent simultaneous groin flap transfer. Lengthening was started 3 days after surgery at a rate of 0.66 mm/d. The pedicle of the groin flap was divided 1 month after the surgery. The healing index (days per cm), which denotes the number of days the external fixator is attached to the bone per centimeter of length gained, was used to evaluate the lengthening efficiency.

RESULTS

The patients were observed for 21.9 ± 9.0 months. The lengthening continued for 29.1 ± 4.5 days, resulting in an additional length of 1.9 ± 0.3 cm.

CONCLUSIONS

The mini-ring Ilizarov external fixator is a simple device for primary metacarpal lengthening. This device can be used with a groin flap for single-stage lengthening of injured thumbs with bone exposure.

TYPE OF STUDY/LEVEL OF EVIDENCE: Therapeutic IV.

Для цитирования: Zhu Yueliang, Xu Yongqing, Pu Shaoquan, Lv Qian, Cai Xingbo, Zhao Yonghui. Metacarpal Lengthening Using a Mini-Ring Ilizarov Device for Thumb Reconstruction.. The Journal of hand surgery. 2023. DOI: 10.1016/j.jhsa.2022.09.008.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.