MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1038/s41467-026-73554-7

Медицинская библиотека · Nature communications · 2026

Near-infrared fluorescence imaging-guided surgery using cRGD-ZW800 to improve surgical resection margins in oral cancer: a phase I/II feasibility trial.

Zweedijk B E, Lauwerends L J, Galema H A, Robinson D J, de Bruijn H S, Abbasi H, March T L, Valentijn A R P M, Pool M, Mast H, Jonker B P, Hardillo J A U, Monserez D, Sewnaik A, Koljenovic S, Verhoef C, Baatenburg de Jong R J, Frangioni J V, Koppes S A, Hilling D E, Vahrmeijer A L, Keereweer S

СтатьяКлиническое исследование I фазыКлиническое исследование II фазыПеревод пока не подготовлен

Аннотация

In oral squamous cell carcinoma (OSCC) surgery, inadequate tumor margins are reported in up to 85% of cases, adversely affecting outcomes. In this prospective, single-center study (n = 31; NCT04191460), we evaluated the safety and imaging feasibility of cRGD-ZW800-1, a near-infrared fluorescent integrin-targeted tracer. The secondary objective was to determine whether intraoperative fluorescence imaging could identify inadequate resection margins and inform surgical decision-making. Patients received 0.01, 0.025, or 0.05 mg/kg cRGD-ZW800-1, and tracer uptake was quantified using in vivo multi-diameter single-fiber reflectance and single-fiber fluorescence spectroscopy to optimize dosing and timing. All doses were well tolerated, achieving tumor-to-background ratios exceeding 4.5, with optimal performance at 0.025 mg/kg. Fluorescence imaging detected all 23 inadequate margins, including nine undetected by conventional assessment (sensitivity 100% versus 70%), altered surgical plans in five cases, and avoided adjuvant radiotherapy in three cases. These findings demonstrate that cRGD-ZW800-1 is safe, tumor-specific, and facilitates intraoperative margin assessment in OSCC.

Для цитирования: Zweedijk B E, Lauwerends L J, Galema H A, Robinson D J, de Bruijn H S, Abbasi H, March T L, Valentijn A R P M, Pool M, Mast H, Jonker B P, Hardillo J A U, Monserez D, Sewnaik A, Koljenovic S, Verhoef C, Baatenburg de Jong R J, Frangioni J V, Koppes S A, Hilling D E, Vahrmeijer A L, Keereweer S. Near-infrared fluorescence imaging-guided surgery using cRGD-ZW800 to improve surgical resection margins in oral cancer: a phase I/II feasibility trial.. Nature communications. 2026. DOI: 10.1038/s41467-026-73554-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.