DOI 10.5137/1019-5149.jtn.42071-22.1
The Evaluation of Low-Profile Surpass EvolveTM Flow Diverter for Endovascular Treatment of Distal Cerebral Artery Aneurysms: A Single-Center Experience.
Аннотация
AIM: To report our experience with the 2.5-mm Surpass EvolveTM flow diverter (FD) in the treatment of distal small cerebral artery aneurysms.
MATERIAL AND
METHODS
This study included 41 patients with 52 aneurysms. Clinical and radiological records and procedural and follow-up outcomes were reviewed retrospectively.
RESULTS
The aneurysm morphology was saccular in 45 patients, dissecting in five patients, and fusiform in two patients. Fifty-two aneurysms were treated with 41 Surpass Evolve FDs. The mean diameters of the proximal and distal parent arteries were 2.56 and 2.17 mm, respectively. The mean duration of follow-up was 16.2 ± 6.6 (6-28) months. Four (10%) patients had acute subarachnoid hemorrhage. In the same session, two patients with two tandem aneurysms and one patient with four tandem aneurysms were treated using a single FD. Intraprocedural hemorrhage and femoral artery pseudoaneurysm occurred in two patients during the procedure. Digital subtraction angiography was performed on 38/41 (92%) patients with 47/52 (88%) having aneurysms. Complete occlusion (OKM D) was observed in 39/47 (82%) aneurysms, and near complete-complete occlusion (OKM C-D) was observed in 46/47 (98%) aneurysms.
CONCLUSION
Endovascular treatment of distal cerebral artery aneurysms with the 2.5-mm Surpass Evolve < sup > TM < /sup > FD provides a high rate of aneurysm occlusion with low periprocedural complications, even in ruptured and tandem aneurysms.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.