Prognostic Value of Thrombus Volume and Interaction With First-Line Endovascular Treatment Device Choice.

van Voorst Henk, Bruggeman Agnetha A E, Andriessen Jurr, Hoving Jan W, Konduri Praneeta R, Yang Wenjin, Kappelhof Manon, Arrarte Terreros Nerea, Roos Yvo B W E M, van Zwam Wim H, van der Lugt Aad, van der Hoorn Anouk, Boiten Jelis, Roosendaal Stefan, Jenniskens Sjoerd, Caan Matthan W A, Marquering Henk A, Emmer Bart J, Majoie Charles B L M, MR CLEAN Registry Investigators

Рандомизированное исследованиеМногоцентровое исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

A larger thrombus in patients with acute ischemic stroke might result in more complex endovascular treatment procedures, resulting in poorer patient outcomes. Current evidence on thrombus volume and length related to procedural and functional outcomes remains contradicting. This study aimed to assess the prognostic value of thrombus volume and thrombus length and whether this relationship differs between first-line stent retrievers and aspiration devices for endovascular treatment.

METHODS

In this multicenter retrospective cohort study, 670 of 3279 patients from the MR CLEAN Registry (Multicenter Randomized Clinical Trial of Endovascular Treatment for Acute Ischemic Stroke in the Netherlands) for endovascularly treated large vessel occlusions were included. Thrombus volume (0.1 mL) and length (0.1 mm) based on manual segmentations and measurements were related to reperfusion grade (expanded Treatment in Cerebral Infarction score) after endovascular treatment, the number of retrieval attempts, symptomatic intracranial hemorrhage, and a shift for functional outcome at 90 days measured with the reverted ordinal modified Rankin Scale (odds ratio >1 implies a favorable outcome). Univariable and multivariable linear and logistic regression were used to report common odds ratios (cORs)/adjusted cOR and regression coefficients (B/aB) with 95% CIs. Furthermore, a multiplicative interaction term was used to analyze the relationship between first-line device choice, stent retrievers versus aspiration device, thrombus volume, and outcomes.

RESULTS

Thrombus volume was associated with functional outcome (adjusted cOR, 0.83 [95% CI, 0.71-0.97]) and number of retrieval attempts (aB, 0.16 [95% CI, 0.16-0.28]) but not with the other outcome measures. Thrombus length was only associated with functional independence (adjusted cOR, 0.45 [95% CI, 0.24-0.85]). Patients with more voluminous thrombi had worse functional outcomes if endovascular treatment was based on first-line stent retrievers (interaction cOR, 0.67 [95% CI, 0.50-0.89]; P=0.005; adjusted cOR, 0.74 [95% CI, 0.55-1.0]; P=0.04).

CONCLUSIONS

In this study, patients with a more voluminous thrombus required more endovascular thrombus retrieval attempts and had a worse functional outcome. Patients with a lengthier thrombus were less likely to achieve functional independence at 90 days. For more voluminous thrombi, first-line stent retrieval compared with first-line aspiration might be associated with worse functional outcome.

Для цитирования: van Voorst Henk, Bruggeman Agnetha A E, Andriessen Jurr, Hoving Jan W, Konduri Praneeta R, Yang Wenjin, Kappelhof Manon, Arrarte Terreros Nerea, Roos Yvo B W E M, van Zwam Wim H, van der Lugt Aad, van der Hoorn Anouk, Boiten Jelis, Roosendaal Stefan, Jenniskens Sjoerd, Caan Matthan W A, Marquering Henk A, Emmer Bart J, Majoie Charles B L M, MR CLEAN Registry Investigators. Prognostic Value of Thrombus Volume and Interaction With First-Line Endovascular Treatment Device Choice.. Stroke. 2023. DOI: 10.1161/strokeaha.122.041606.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.