Environmental Contamination of Contact Precaution and Non-Contact Precaution Patient Rooms in Six Acute Care Facilities.

Tanner Windy D, Leecaster Molly K, Zhang Yue, Stratford Kristina M, Mayer Jeanmarie, Visnovsky Lindsay D, Alhmidi Heba, Cadnum Jennifer L, Jencson Annette L, Koganti Sreelatha, Bennett Christina P, Donskey Curtis J, Noble-Wang Judith, Reddy Sujan C, Rose Laura J, Watson Lauren, Ide Emma, Wipperfurth Tyler, Safdar Nasia, Arasim Maria, Macke Colleen, Roman Patti, Krein Sarah L, Loc-Carrillo Catherine, Samore Matthew H

СтатьяПоддержка правительства СШАПоддержка службы здравоохранения СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Environmental contamination is an important source of hospital multidrug-resistant organism (MDRO) transmission. Factors such as patient MDRO contact precautions (CP) status, patient proximity to surfaces, and unit type likely influence MDRO contamination and bacterial bioburden levels on patient room surfaces. Identifying factors associated with environmental contamination in patient rooms and on shared unit surfaces could help identify important environmental MDRO transmission routes.

METHODS

Surfaces were sampled from MDRO CP and non-CP rooms, nursing stations, and mobile equipment in acute care, intensive care, and transplant units within 6 acute care hospitals using a convenience sampling approach blinded to cleaning events. Precaution rooms had patients with clinical or surveillance tests positive for methicillin-resistant Staphylococcus aureus, vancomycin-resistant enterococci, carbapenem-resistant Enterobacteriaceae or Acinetobacter within the previous 6 months, or Clostridioides difficile toxin within the past 30 days. Rooms not meeting this definition were considered non-CP rooms. Samples were cultured for the above MDROs and total bioburden.

RESULTS

Overall, an estimated 13% of rooms were contaminated with at least 1 MDRO. MDROs were detected more frequently in CP rooms (32% of 209 room-sample events) than non-CP rooms (12% of 234 room-sample events). Surface bioburden did not differ significantly between CP and non-CP rooms or MDRO-positive and MDRO-negative rooms.

CONCLUSIONS

CP room surfaces are contaminated more frequently than non-CP room surfaces; however, contamination of non-CP room surfaces is not uncommon and may be an important reservoir for ongoing MDRO transmission. MDRO contamination of non-CP rooms may indicate asymptomatic patient MDRO carriage, inadequate terminal cleaning, or cross-contamination of room surfaces via healthcare personnel hands.

Для цитирования: Tanner Windy D, Leecaster Molly K, Zhang Yue, Stratford Kristina M, Mayer Jeanmarie, Visnovsky Lindsay D, Alhmidi Heba, Cadnum Jennifer L, Jencson Annette L, Koganti Sreelatha, Bennett Christina P, Donskey Curtis J, Noble-Wang Judith, Reddy Sujan C, Rose Laura J, Watson Lauren, Ide Emma, Wipperfurth Tyler, Safdar Nasia, Arasim Maria, Macke Colleen, Roman Patti, Krein Sarah L, Loc-Carrillo Catherine, Samore Matthew H. Environmental Contamination of Contact Precaution and Non-Contact Precaution Patient Rooms in Six Acute Care Facilities.. Clinical infectious diseases : an official publication of the Infectious Diseases Society of America. 2021. DOI: 10.1093/cid/ciaa1602.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.