MedElevator Войти в исследования
← Поиск публикаций

DOI 10.21037/jtd-24-1169

Медицинская библиотека · Journal of thoracic disease · 2024

Changes in stent-graft orientation after frozen elephant trunk treatment in aortic arch aneurysm.

Takahashi Yosuke, Morisaki Akimasa, Nishiya Kenta, Inno Gouki, Kawase Takumi, Nishimoto Yukihiro, Nagao Munehide, Noda Kazuki, Nangoya Ryo, Shibata Toshihiko

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Changes in stent graft (SG) orientation after frozen elephant trunk (FET) treatment for aortic arch aneurysms are not well understood. This study investigated changes in SG orientation and their effects on aortic events after FET for aortic arch aneurysms.

METHODS

This study included 57 patients with true aneurysms who underwent elective total arch replacement using FET between 2016 and 2023. Postoperative SG angle, descending aortic (DA) diameter at the end of the SG, and the DA angle were measured retrospectively by using enhanced computed tomography (CT).

RESULTS

Median patient age was 74 years. The median stent size was 33 mm, and the stent length was 12 cm (range, 23-37 mm and 6-15 cm). Enhanced CT showed that all the patients had completely thrombosed aneurysms after the procedure. Aortic events (dissection or type Ib leaks) were observed in four patients during the follow-up period. The diameter of the DA at the end of the SG and the DA angle increased in recent periods (P=0.04 and P=0.01, respectively). The SG angle changed to an obtuse angle in the recent periods (P<0.0001). The probability of postoperative aortic events did not correlate with changes in SG orientation but with the ratio of recent postoperative descending diameter to preoperative descending diameter (P=0.04).

CONCLUSIONS

The descending aorta into which the SG was inserted showed flattening and widening movements owing to the spiring back force. One of the factors related to aortic events was dilation of the postoperative DA due to oversizing of the SG.

Для цитирования: Takahashi Yosuke, Morisaki Akimasa, Nishiya Kenta, Inno Gouki, Kawase Takumi, Nishimoto Yukihiro, Nagao Munehide, Noda Kazuki, Nangoya Ryo, Shibata Toshihiko. Changes in stent-graft orientation after frozen elephant trunk treatment in aortic arch aneurysm.. Journal of thoracic disease. 2024. DOI: 10.21037/jtd-24-1169.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.