Non-contrast-enhanced MR-angiography of the abdominal arteries: intraindividual comparison between relaxation-enhanced angiography without contrast and triggering (REACT) and 4D contrast-enhanced MR-angiography.

СтатьяСравнительное исследованиеПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Gietzen Carsten, Janssen Jan Paul, Görtz Lukas, Kaya Kenan, Gietzen Thorsten, Gertz Roman Johannes, Pennig Henry, Seuthe Katharina, Maintz David, Rauen Philip S, Persigehl Thorsten, Weiss Kilian, Pennig Lenhard

Аннотация

PURPOSE: To evaluate Relaxation-Enhanced Angiography without Contrast and Triggering (REACT), a novel 3D isotropic flow-independent non-contrast-enhanced magnetic resonance angiography (non-CE-MRA) for imaging of the abdominal arteries, by comparing image quality and assessment of vessel stenosis intraindidually with 4D CE-MRA.

METHODS: Thirty patients (mean age 35.7 ± 16.8 years; 20 females) referred for the assessment of the arterial abdominal vasculature at 3 T were included in this retrospective, single-centre study. The protocol comprised both 4D CE-MRA and REACT (navigator-triggering, Compressed SENSE factor 10, nominal scan time 02:54 min, and reconstructed voxel size 0.78 × 0.78 × 0.85  mm3). Two radiologists independently evaluated 14 abdominal artery segments for stenoses, anatomical variants, and vascular findings (aortic dissection, abdominal aorta aneurysms and its branches). Subjective image quality was assessed using a 4-point Likert scale (1 = non-diagnostic, 4 = excellent).

RESULTS: REACT had a total acquisition time of 5:36 ± 00:40 min, while 4D CE-MRA showed a total acquisition time (including the native scan and bolus tracking sequence) of 3:45 ± 00:59 min (p = 0.001). Considering 4D CE-MRA as the reference standard, REACT achieved a sensitivity of 87.5% and specificity of 100.0% for relevant (≥ 50%) stenosis while detecting 89.5% of all vascular findings other than stenosis. For all vessels combined, subjective vessel quality was slightly higher in 4D CE-MRA (3.0 [IQR: 2.0; 4.0.]; P = 0.040), although comparable to REACT (3.0 [IQR: 2.0; 3.5]).

CONCLUSION: In a short scan time of about 5 min, REACT provides good diagnostic performance for detection of relevant stenoses, variants, and vascular findings of the abdominal arteries, while yielding to 4D CE-MRA comparable image quality.