MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ejrad.2025.112453

Медицинская библиотека · European journal of radiology · 2025

Does BMI influence AI and human reader lung nodule detection in low-dose chest CT?

Sourlos Nikos, van Tuinen Marcel, Sidorenkov Grigory, de Jonge Gonda, Schalekamp Steven, Pelgrim Gert Jan, Greuter Marcel, Rook Mieneke, Prokop Mathias, van Ooijen Peter, Vliegenthart Rozemarijn

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: Body mass index (BMI) can influence image quality in low dose computed tomography (LDCT) through higher image noise levels. We evaluated whether BMI affects lung nodule detection by artificial intelligence (AI) software and a human reader.

METHOD: The study utilized chest LDCT scans from the Lifelines cohort. We included 1.5 % participants at highest BMI (mean = 39.8, sd = 3.0), and 1.5 % at lowest BMI (mean = 18.7, sd = 0.9). Nodule detection was performed by AI software and by a trained human reader (HR). Two chest radiologists reviewed detection discrepancies, with disagreements resolved by an expert radiologist. Sensitivity and false positives per scan (FP/scan) were compared between BMI groups, for AI versus HR.

RESULTS

There were 176 participants in both groups, with 131 nodules in high BMI, and 136 in low BMI. AI detected 356 nodular findings and HR 251, including 154 nodules found by both. AI's sensitivity was 0.75 (95 % confidence interval 0.66-0.82) in high BMI, and 0.80 (0.72-0.86) in low BMI groups (p = 0.37). FP/scan was 0.30 and 0.55 in high and low BMI, respectively (p = 0.005). HR's sensitivity was 0.76 (0.68-0.83) in high BMI, and 0.84 (0.76-0.89) in low BMI groups (p = 0.17), with FP/scan of 0.05 and 0.16, respectively (p = 0.09). In both BMI groups, AI had more FP/scan than the human reader (p < 0.001).

CONCLUSIONS

Sensitivity for lung nodule detection in LDCT was not significantly different for high versus low BMI, either for AI or human reader. Compared to the human reader, AI had higher FP/scan in both BMI groups.

Для цитирования: Sourlos Nikos, van Tuinen Marcel, Sidorenkov Grigory, de Jonge Gonda, Schalekamp Steven, Pelgrim Gert Jan, Greuter Marcel, Rook Mieneke, Prokop Mathias, van Ooijen Peter, Vliegenthart Rozemarijn. Does BMI influence AI and human reader lung nodule detection in low-dose chest CT?. European journal of radiology. 2025. DOI: 10.1016/j.ejrad.2025.112453.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.