m+Medelevator.RU
← Поиск публикаций
Journal of the American Medical Informatics Association : JAMIA · 2025

Including AI in diffusion-weighted breast MRI has potential to increase reader confidence and reduce workload.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Bounias Dimitrios, Simons Lina, Baumgartner Michael, Ehring Chris, Neher Peter, Kapsner Lorenz A, Kovacs Balint, Floca Ralf, Jaeger Paul F, Eberle Jessica, Hadler Dominique, Laun Frederik B, Ohlmeyer Sabine, Maier-Hein Lena, Uder Michael, Wenkel Evelyn, Maier-Hein Klaus H, Bickelhaupt Sebastian

Аннотация

OBJECTIVES: Breast diffusion-weighted imaging (DWI) has shown potential as a standalone imaging technique for certain indications, eg, supplemental screening of women with dense breasts. This study evaluates an artificial intelligence (AI)-powered computer-aided diagnosis (CAD) system for clinical interpretation and workload reduction in breast DWI.

MATERIALS AND METHODS: This retrospective IRB-approved study included: n = 824 examinations for model development (2017-2020) and n = 235 for evaluation (01/2021-06/2021). Readings were performed by three readers using either the AI-CAD or manual readings. BI-RADS-like (Breast Imaging Reporting and Data System) classification was based on DWI. Histopathology served as ground truth. The model was nnDetection-based, trained using 5-fold cross-validation and ensembling. Statistical significance was determined using McNemar's test. Inter-rater agreement was calculated using Cohen's kappa. Model performance was calculated using the area under the receiver operating curve (AUC).

RESULTS: The AI-augmented approach significantly reduced BI-RADS-like 3 calls in breast DWI by 29% (P =.019) and increased interrater agreement (0.57 ± 0.10 vs 0.49 ± 0.11), while preserving diagnostic accuracy. Two of the three readers detected more malignant lesions (63/69 vs 59/69 and 64/69 vs 62/69) with the AI-CAD. The AI model achieved an AUC of 0.78 (95% CI: [0.72, 0.85]; P <.001), which increased for women at screening age to 0.82 (95% CI: [0.73, 0.90]; P <.001), indicating a potential for workload reduction of 20.9% at 96% sensitivity.

DISCUSSION AND CONCLUSION: Breast DWI might benefit from AI support. In our study, AI showed potential for reduction of BI-RADS-like 3 calls and increase of inter-rater agreement. However, given the limited study size, further research is needed.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты