Objective
To investigate the feasibility, efficacy and safety of semiconductor laser in situ fenestration of type A aortic dissection during thoracic endovascular aortic repair.
Methods
The clinical data of 68 patients with type A aortic dissection treated by semiconductor laser in situ fenestration from June 2016 to January 2020 in Department of Vascular Surgery, Shanghai Ninth People's Hospital Affiliated to Shanghai Jiaotong University were analyzed retrospectively. Of the patients, 45 were male, 23 were female, the mean age was (52±14) years. The technical success rate and complication rates were assessed.
Results
The technical success rate of 68 patients was 92.6% (63/68), only 5 patients failed due to the complex aortic arch type, 3 patients underwent chimney stent implantation, 2 patients underwent artificial vessel bypass. During the perioperative period, 1 patient died due to severe pulmonary infection, 4 patients developed neurological symptoms such as cerebral infarction after surgery, and the remaining patients had no related complications. Postoperative CTA follow-up indicated that the primary intercalation rupture was completely closed, and the main and branch stents were patency, 8 (8.8%) type Ⅰ leakage were occurred.
Conclusion
It showed that in situ semiconductor laser fenestration is a feasible, effective and safe method to treat type A aortic dissection.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.