MedElevator Войти в исследования
← Поиск публикаций
Медицинская библиотека · Clinical laboratory · 2011

Evaluation of arsenic, cadmium, lead, and nickel in biological samples (scalp hair, serum, blood, and urine) of Pakistani viral hepatitis (A - E) patients and controls.

Afridi Hassan Imran, Kazi Tasneem Gul, Shah Faheem, Sheikh Hafeez-ur-Rehman, Kolachi Nida Fatima

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

The aim of present study was to compare the level of arsenic (As), cadmium (Cd), lead (Pb), and nickel (Ni) in biological samples (serum, blood, urine, and scalp hair) of patients suffering from different viral hepatitis (A, B, C, D, and E; n = 521) of both genders, age range 31 - 45 years. For comparative study, 255 age-matched control subjects of both genders residing in the same city were selected as referents.

METHODS

The digests of all biological samples were analysed for Cd, Pb, and Ni by electrothermal atomic absorption spectrometry (ETAAS). The validity and accuracy of the methodology was checked by using certified reference materials (CRMs) and with those values obtained by conventional wet acid digestion method on the same CRMs.

RESULTS

The results of this study showed that the mean values of As, Cd, Ni, and Pb were higher in blood, serum, and scalp hair samples of hepatitis patients than age-matched control subjects. The urinary levels of these elements were found to be higher in the hepatitis patients than in the age-matched healthy controls (p < 0.001).

CONCLUSIONS

These results are consistent with literature-reported data, confirming that the overload of these toxic elements can directly cause lipid peroxidation and eventually hepatic damage.

Для цитирования: Afridi Hassan Imran, Kazi Tasneem Gul, Shah Faheem, Sheikh Hafeez-ur-Rehman, Kolachi Nida Fatima. Evaluation of arsenic, cadmium, lead, and nickel in biological samples (scalp hair, serum, blood, and urine) of Pakistani viral hepatitis (A - E) patients and controls.. Clinical laboratory. 2011.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.