MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s12630-010-9412-3

Медицинская библиотека · Canadian journal of anaesthesia = Journal canadien d'anesthesie · 2010

Less perilaryngeal gas leakage with SLIPA™ than with LMA-ProSeal™ in paralyzed patients.

Woo Young Cheol, Cha Su Man, Kang Hyun, Baek Chong Wha, Jung Yong Hun, Kim Jin Yun, Koo Gill Hoi, Park Sun Gyoo, Kim Seong Deok

Сравнительное исследованиеСтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: The aim of this study was to compare the Streamlined Liner of the Pharynx Airway (SLIPA™) with the ProSeal Laryngeal Mask Airway (LMA-ProSeal™) in mechanically ventilated paralyzed patients undergoing laparoscopic gynecologic surgery.

METHODS

One hundred and one patients were allocated randomly to SLIPA (n = 50) or to LMA-ProSeal (n = 51) treatment groups. After induction of general anesthesia and insertion of the assigned supralaryngeal airway (SLA) device, we made note of the occurrence of any gastric insufflation and perilaryngeal leakage. We then evaluated the anatomical fit of the SLA device using a fibreoptic bronchoscope, and we assessed the airway sealing pressure and respiratory mechanics with change in head position and during peritoneal insufflation. After surgery, we evaluated the severity of postoperative sore throat and the presence of blood or regurgitated fluid on the SLA device.

RESULTS

The insertion success rate, gastric insufflation, perilaryngeal leakage, anatomical fit, airway sealing pressure, respiratory mechanics, severity of sore throat, and incidence of blood and regurgitated fluid on the device were similar between the two groups. The incidence of perilaryngeal leakage with changes in the patient's head position was lower with the SLIPA group than with the LMA-ProSeal group (3/50 vs 11/51, respectively; P = 0.026). During peritoneal insufflation, perilaryngeal leakage did not occur with the SLIPA but occurred in four cases with the LMA-ProSeal (P = 0.045).

CONCLUSION

Both the SLIPA and the LMA-ProSeal can be used effectively and without severe complications in paralyzed patients undergoing laparoscopic gynecological surgery. However, the SLIPA offers the advantage of less perilaryngeal gas leakage than the LMA-ProSeal with change in head position and during insufflation of the peritoneal cavity. This trial is registered with ANZCTR (ACTRN12609000914268).

Для цитирования: Woo Young Cheol, Cha Su Man, Kang Hyun, Baek Chong Wha, Jung Yong Hun, Kim Jin Yun, Koo Gill Hoi, Park Sun Gyoo, Kim Seong Deok. Less perilaryngeal gas leakage with SLIPA™ than with LMA-ProSeal™ in paralyzed patients.. Canadian journal of anaesthesia = Journal canadien d'anesthesie. 2010. DOI: 10.1007/s12630-010-9412-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.