BACKGROUND

Intra-organ and intra-vascular pressures can be used to estimate intra-abdominal pressure. The aim of this prospective, interventional study was to assess the effect of PEEP on the accuracy of pressure estimation at different measurement sites in a model of increased abdominal pressure.

METHODS

Catheters for pressure measurement were inserted into the stomach, urinary bladder, peritoneal cavity, pulmonary artery and inferior vena cava of 12 pigs. The pressures were recorded simultaneously at baseline, during 10 cm H20 PEEP, external abdominal pressure (7 kg weight) plus PEEP, external abdominal pressure without PEEP, and again under baseline conditions. RESULTS (MEAN +/- SD): PEEP alone increased diastolic pulmonary artery and inferior vena cava pressure but had no effect on the other pressures. PEEP and external abdominal pressure increased intraperitoneal pressure from 6 +/- 1 mm Hg to 9 +/- 2 mm Hg, urinary bladder pressure from 6 +/- 2 mm Hg to 11 +/- 2 mm Hg (p = 0.012), intragastric pressure from 6 +/- 2 mm Hg to 11 +/- 2 mm Hg (all p <or= 0.001), and inferior vena cava pressure from 11 +/- 4 mm Hg to 15 +/- 4 mm Hg (p = 0.01). Removing PEEP and maintaining extraabdominal pressure was associated with a decrease in pulmonary artery diastolic but not in any of the other pressures. There was a significant correlation among all pressures. Bias (-1 mm Hg) and limits of agreement (3 to -5 mm Hg) were similar for the comparisons of absolute intraperitoneal pressure with intra-gastric and urinary bladder pressure, but larger for the comparison between intraperitoneal and inferior vena cava pressure (-5, 0 to -11 mm Hg). Bias (0 to -1 mm Hg) and limits of agreement (3 to -4 mm Hg) for pressure changes were similar for all comparisons

CONCLUSIONS

Our data suggest that pressure changes induced by external abdominal pressure were not modified by changing PEEP between 0 and 10 cm H20.

Для цитирования: Jakob Stephan M, Knuesel Rafael, Tenhunen Jyrki J, Pradl Richard, Takala Jukka. Increasing abdominal pressure with and without PEEP: effects on intra-peritoneal, intra-organ and intra-vascular pressures.. BMC gastroenterology. 2010. DOI: 10.1186/1471-230x-10-70.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.