MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/aas.14517

Медицинская библиотека · Acta anaesthesiologica Scandinavica · 2024

The performance and complications of long peripheral venous catheters: A retrospective single-centre study.

Krath Julie, Fredskilde Jesper, Christensen Simone Krogh, Baltsen Cecilie Dahl, Valentin Kamilla, Offersen Ryan, Juhl-Olsen Peter

СтатьяНаблюдательное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

Intravenous therapies are essential for hospitalised patients. The rapid dissemination of portable ultrasound machines has eased ultrasound-guided intravenous access and facilitated increased use of long peripheral venous catheters (LPCs). This study aimed to evaluate the clinical performance and complications of LPCs.

METHODS

Retrospective, observational single-site study. Data from all consecutively inserted LPCs during a period of 18 months was evaluated. The primary endpoint was the all-cause incidence rate of catheter removal. Secondary endpoints included specific reasons for the catheter removal and the associations between predefined characteristics of the patients, the infusions and the catheters with catheter failure.

RESULTS

During the period, 751 PVCs were inserted in 457 patients. The reasons for catheter removal were recorded in 563 cases. The overall incidence rate of catheter removal was 95.8/1000 catheter days (95% CI 88.4-103.8). The median dwell time was 8 days (IQR 5-14), and the total dwell time was 6136 days. Catheter failure occurred in 283 (50.3%) cases, of which the most common cause was phlebitis (n = 101, 17.9%). In multivariable analyses, the use of the cephalic vein was significantly associated with both all-cause catheter failure (p < .001) and catheter failure due to phlebitis (p < .001). In multivariable analyses, vancomycin infusion was not significantly associated with all-cause catheter failure (HR 1.15 (0.55-2.42), p = .71) or catheter failure due to phlebitis (HR 1.49 (0.49-4.53), p = .49).

CONCLUSION

The overall incidence rate of catheter removal was 95.8/1000 catheter days, and the most common causes of catheter failure were phlebitis, infiltration and unintended catheter removal. The use of the cephalic vein was significantly associated with catheter failure in multivariable analyses. We did not find an association between vancomycin infusion and catheter failure in multivariable analyses.

Для цитирования: Krath Julie, Fredskilde Jesper, Christensen Simone Krogh, Baltsen Cecilie Dahl, Valentin Kamilla, Offersen Ryan, Juhl-Olsen Peter. The performance and complications of long peripheral venous catheters: A retrospective single-centre study.. Acta anaesthesiologica Scandinavica. 2024. DOI: 10.1111/aas.14517.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.