Preventing device-associated infections in US hospitals: national surveys from 2005 to 2013.

Krein Sarah L, Fowler Karen E, Ratz David, Meddings Jennifer, Saint Sanjay

СтатьяПоддержка исследования: вне правительства СШАПоддержка правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Numerous initiatives have focused on reducing device-associated infections, contributing to an overall decrease in infections nationwide. To better understand factors associated with this decline, we assessed the use of key practices to prevent device-associated infections by US acute care hospitals from 2005 to 2013.

METHODS

We mailed surveys to infection preventionists at a national random sample of ∼600 US acute care hospitals in 2005, 2009 and 2013. Our survey asked about the use of practices to prevent the 3 most common device-associated infections: central line-associated bloodstream infection (CLABSI), ventilator-associated pneumonia (VAP) and catheter-associated urinary tract infection (CAUTI). Using sample weights, we estimated the per cent of hospitals reporting regular use (a score of 4 or 5 on a scale from 1 (never use) to 5 (always use)) of prevention practices from 2005 to 2013.

RESULTS

The response rate was about 70% in all 3 periods. Use of most recommended prevention practices increased significantly over time. Among those showing the greatest increase were use of an antimicrobial dressing for preventing CLABSI (25-78%, p<0.001), use of an antimicrobial mouth rinse for preventing VAP (41-79%, p<0.001) and use of catheter removal prompts for preventing CAUTI (9-53%, p<0.001). Likewise, a significant increase in facility-wide surveillance was found for all three infections. Practices for which little change was observed included use of antimicrobial catheters to prevent either CLABSI or CAUTI.

CONCLUSIONS

US hospitals have responded to the call to reduce infection by increasing use of key recommended practices. Vigilance is needed to ensure sustained improvement and additional strategies may still be required, given an apparent continuing lag in CAUTI prevention efforts.

Для цитирования: Krein Sarah L, Fowler Karen E, Ratz David, Meddings Jennifer, Saint Sanjay. Preventing device-associated infections in US hospitals: national surveys from 2005 to 2013.. BMJ quality & safety. 2015. DOI: 10.1136/bmjqs-2014-003870.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.