MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1080/14779072.2022.2153118

Медицинская библиотека · Expert review of cardiovascular therapy · 2022

Valve-in-valve transcatheter aortic valve replacement versus redo aortic valve replacement: which procedure for which patient?

Hutt Erika, Mehra Nandini, Desai Milind Y

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

Bioprosthetic aortic valves are increasingly being utilized in a younger population due to improved durability and possibility for future valve-in-valve replacement. This has resulted in a larger population of patients with bioprosthetic aortic valve degeneration requiring re-intervention. Despite no head-to-head comparisons between redo surgical aortic valve replacement (SAVR) and valve-in-valve transcatheter aortic valve replacement (ViV TAVR), observational studies suggest a comparable long-term risk between which led to the incorporation of ViV TAVR to current guidelines.

AREAS COVERED: This article summarizes the comparative performance of redo SAVR versus ViV TAVR in patients with bioprosthetic valve dysfunction and provides a guide to better understand which procedure is best for which patient.

EXPERT OPINION: With the rising use of TAVR, we will be confronted with more bioprosthetic aortic valve degeneration requiring re-intervention. Based on the available evidence and expert consensus, we propose that patients with bioprosthetic aortic valve degeneration be treated with ViV TAVR if they have a history of radiation heart disease, prohibitive surgical risk, and multiple sternotomies; while patients with small prostheses, history of infective endocarditis, those at high risk for coronary obstruction, and those with need for other cardiac surgery will be managed with redo SAVR.

Для цитирования: Hutt Erika, Mehra Nandini, Desai Milind Y. Valve-in-valve transcatheter aortic valve replacement versus redo aortic valve replacement: which procedure for which patient?. Expert review of cardiovascular therapy. 2022. DOI: 10.1080/14779072.2022.2153118.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.