MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ajic.2014.04.018

Медицинская библиотека · American journal of infection control · 2014

A Trial of electronic surveillance feedback for quality improvement at Nurses Improving Care for Healthsystem Elders (NICHE) hospitals.

Wald Heidi L, Bandle Brian, Richard Angela A, Min Sung-Joon, Capezuti Elizabeth

СтатьяРандомизированное исследованиеПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПоддержка службы здравоохранения СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Catheter-associated urinary tract infection (CAUTI) risk is directly related to duration of indwelling urinary catheters (IUCs), rising beyond 2 days of catheterization.

METHODS

We conducted a cluster randomized study in nonintensive care units of Nurses Improving Care for Healthsystem Elders (NICHE) hospitals. Electronic surveillance data were used in an audit and feedback intervention for frontline nurses to reduce IUC duration. Multivariable methods were used to identify the difference in average IUC duration and proportion of patients with IUC duration <3 days between patients in an early intervention group and a delayed intervention group, adjusting for patient, unit, and hospital characteristics.

RESULTS

A total of 24 units at 19 NICHE hospitals reported 13,499 adult patients with IUCs over 18 months. Early and delayed intervention groups had important baseline differences in IUC utilization. Use of evidence-based CAUTI prevention measures increased during study participation. In multivariable analysis, the average IUC duration and proportion of patients with IUC duration <3 days were not improved in the early intervention group compared with the delayed intervention group.

CONCLUSION

The impact of the audit and feedback intervention was not significant despite the uptake of evidence-based CAUTI prevention practices.

Для цитирования: Wald Heidi L, Bandle Brian, Richard Angela A, Min Sung-Joon, Capezuti Elizabeth. A Trial of electronic surveillance feedback for quality improvement at Nurses Improving Care for Healthsystem Elders (NICHE) hospitals.. American journal of infection control. 2014. DOI: 10.1016/j.ajic.2014.04.018.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.