DOI 10.1177/1526602816671740

Медицинская библиотека · Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists · 2016

Comparative Effectiveness of Plain Balloon Angioplasty, Bare Metal Stents, Drug-Coated Balloons, and Drug-Eluting Stents for the Treatment of Infrapopliteal Artery Disease: Systematic Review and Bayesian Network Meta-analysis of Randomized Controlled Trials.

Katsanos Konstantinos, Kitrou Panagiotis, Spiliopoulos Stavros, Diamantopoulos Athanasios, Karnabatidis Dimitris

СтатьяСистематический обзорNetwork Meta-AnalysisПеревод пока не подготовлен

Аннотация

PURPOSE: To report a Bayesian network meta-analysis of randomized controlled trials (RCTs) comparing bare metal stents (BMS), paclitaxel-coated balloons (PCBs), and drug-eluting stents (DES) with balloon angioplasty (BA) or with each other in the infrapopliteal arteries.

METHODS

Sixteen RCTs comprising 1805 patients with 1-year median follow-up were analyzed. Bayesian random effects binomial models were employed (WinBUGS). Relative treatment effects were expressed as odds ratios (ORs) with 95% credible intervals (CrI), and the cumulative rank probabilities were calculated to provide hierarchies of competing treatments. Quality of evidence (QoE) was assessed with the GRADE (grading of recommendations assessment, development, and evaluation) system. Sensitivity, heterogeneity, and consistency analyses were performed.

RESULTS

There was high QoE that infrapopliteal DES significantly reduced restenosis compared with BMS (OR 0.26, 95% CrI 0.12 to 0.51) and BA (OR 0.22, 95% CrI 0.11 to 0.45). Likewise, DES significantly reduced target lesion revascularization (TLR) compared with BA (OR 0.41, 95% CrI 0.22 to 0.75) and BMS (OR 0.26, 95% CrI 0.15 to 0.45). Paclitaxel-coated balloons also reduced TLR compared with BA (OR 0.55, 95% CrI 0.34 to 0.90) and BMS (OR 0.35, 95% CrI 0.18 to 0.67), but QoE was low to moderate. BA had lower TLR than BMS (OR 0.63, 95% CrI 0.40 to 0.99) with high QoE. DES was the only treatment that significantly reduced limb amputations compared with BA (OR 0.58, 95% CrI 0.35 to 0.96), PCB (OR 0.51, 95% CrI 0.26 to 0.98), or BMS (OR 0.38, 95% CrI 0.19 to 0.72) with moderate to high QoE. DES also significantly improved wound healing compared with BA (OR 2.02, 95% CrI 1.01 to 4.07) or BMS (OR 3.45, 95% CrI 1.41 to 8.73) with high QoE. Results were stable on sensitivity and meta-regression analyses without any significant publication bias or inconsistency.

CONCLUSION

Infrapopliteal DES were associated with significantly lower rates of restenosis, TLR, and amputations and improved wound healing compared to BA and BMS. DES also significantly reduced amputations compared with PCB.

Для цитирования: Katsanos Konstantinos, Kitrou Panagiotis, Spiliopoulos Stavros, Diamantopoulos Athanasios, Karnabatidis Dimitris. Comparative Effectiveness of Plain Balloon Angioplasty, Bare Metal Stents, Drug-Coated Balloons, and Drug-Eluting Stents for the Treatment of Infrapopliteal Artery Disease: Systematic Review and Bayesian Network Meta-analysis of Randomized Controlled Trials.. Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists. 2016. DOI: 10.1177/1526602816671740.