MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcin.2016.07.002

Медицинская библиотека · JACC. Cardiovascular interventions · 2016

Feasibility and Safety of Robotic Peripheral Vascular Interventions: Results of the RAPID Trial.

Mahmud Ehtisham, Schmid Florian, Kalmar Peter, Deutschmann Hannes, Hafner Franz, Rief Peter, Brodmann Marianne

Клиническое исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVES

The goal of this study was to evaluate the feasibility and safety of a robotic-assisted platform (CorPath 200, Corindus Vascular Robotics, Waltham, Massachusetts) for treating peripheral artery disease.

BACKGROUND

A robotic-assisted platform for percutaneous coronary intervention is available for treating coronary artery disease.

METHODS

In this prospective single-arm trial, patients with symptomatic peripheral artery disease (Rutherford class 2 to 5) affecting the femoropoplital artery were enrolled. Endpoints evaluated were: 1) device technical success, defined as successful cannulation of the target vessel with the robotic system; 2) device safety, defined as absence of device related serious adverse event (hospitalization, prolonged hospitalization, life threatening, or resulted in death); and 3) clinical procedural success, defined as <50% residual stenosis without an unplanned switch to manual assistance or device-related serious adverse event in the periprocedural period.

RESULTS

The study enrolled 20 subjects (65.5 ± 9.3 years of age; 70% male) with primarily Rutherford class 2 to 3 (90%) symptoms. A total of 29 lesions (lesion length: 33.1 ± 15.5 mm) were treated with the majority (89.7%) being located in the superficial femoral artery. Device technical success, safety and clinical procedural success were all 100% with provisional stenting required in 34.5% of lesions. Fluoroscopy time (7.1 ± 3.2 min) and contrast use (73.3 ± 9.2 ml) compared favorably with studies in similar patient cohorts. There were no adverse events associated with the use of the robotic system.

CONCLUSIONS

These data demonstrate the feasibility and safety of using a robotic-assisted platform for performing peripheral arterial revascularization.

Для цитирования: Mahmud Ehtisham, Schmid Florian, Kalmar Peter, Deutschmann Hannes, Hafner Franz, Rief Peter, Brodmann Marianne. Feasibility and Safety of Robotic Peripheral Vascular Interventions: Results of the RAPID Trial.. JACC. Cardiovascular interventions. 2016. DOI: 10.1016/j.jcin.2016.07.002.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.