MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcv.2021.104874

Медицинская библиотека · Journal of clinical virology : the official publication of the Pan American Society for Clinical Virology · 2021

Diagnostic accuracy and feasibility of patient self-testing with a SARS-CoV-2 antigen-detecting rapid test.

Lindner Andreas K, Nikolai Olga, Rohardt Chiara, Kausch Franka, Wintel Mia, Gertler Maximilian, Burock Susen, Hörig Merle, Bernhard Julian, Tobian Frank, Gaeddert Mary, Lainati Federica, Corman Victor M, Jones Terry C, Sacks Jilian A, Seybold Joachim, Denkinger Claudia M, Mockenhaupt Frank P

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Considering the possibility of nasal self-sampling and the ease of use in performing SARS-CoV-2 antigen-detecting rapid diagnostic tests (Ag-RDTs), self-testing is a feasible option.

OBJECTIVE

The goal of this study was a head-to-head comparison of diagnostic accuracy of patient self-testing with professional testing using a SARS-CoV-2 Ag-RDT.

STUDY

DESIGN

We performed a manufacturer-independent, prospective diagnostic accuracy study of nasal mid-turbinate self-sampling and self-testing with symptomatic adults using a WHO-listed SARS-CoV-2 Ag-RDT. Procedures were observed without intervention. For comparison, Ag-RDTs with nasopharyngeal sampling were professionally performed. Estimates of agreement, sensitivity, and specificity relative to RT-PCR on a combined oro-/nasopharyngeal sample were calculated. Feasibility was evaluated by observer and participant questionnaires.

RESULTS

Among 146 symptomatic adults, 40 (27.4%) were RT-PCR-positive for SARS-CoV-2. Sensitivity with self-testing was 82.5% (33/40; 95% CI 68.1-91.3), and 85.0% (34/40; 95% CI 70.9-92.9) with professional testing. At high viral load (≥7.0 log10 SARS-CoV-2 RNA copies/ml), sensitivity was 96.6% (28/29; 95% CI 82.8-99.8) for both self- and professional testing. Deviations in sampling and testing were observed in 25 out of the 40 PCR-positives. Most participants (80.9%) considered the Ag-RDT as easy to perform.

CONCLUSION

Laypersons suspected for SARS-CoV-2 infection were able to reliably perform the Ag-RDT and test themselves. Procedural errors might be reduced by refinement of the instructions for use or the product design/procedures. Self-testing allows more wide-spread and frequent testing. Paired with the appropriate information of the public about the benefits and risks, self-testing may have significant impact on the pandemic.

Для цитирования: Lindner Andreas K, Nikolai Olga, Rohardt Chiara, Kausch Franka, Wintel Mia, Gertler Maximilian, Burock Susen, Hörig Merle, Bernhard Julian, Tobian Frank, Gaeddert Mary, Lainati Federica, Corman Victor M, Jones Terry C, Sacks Jilian A, Seybold Joachim, Denkinger Claudia M, Mockenhaupt Frank P. Diagnostic accuracy and feasibility of patient self-testing with a SARS-CoV-2 antigen-detecting rapid test.. Journal of clinical virology : the official publication of the Pan American Society for Clinical Virology. 2021. DOI: 10.1016/j.jcv.2021.104874.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.