MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jvir.2016.05.042

Медицинская библиотека · Journal of vascular and interventional radiology : JVIR · 2016

Retrospective Multicenter Comparison of S.M.A.R.T. CONTROL and MISAGO Stents in Treatment of Femoropopliteal Lesions.

Suzuki Kenji, Takahara Mitsuyoshi, Shintani Yoshiaki, Tanaka Akiko, Soga Yoshimitsu, Yamaoka Terutoshi, Tosaka Atsushi, Sasaki Shinya, Kawasaki Daizo, Tsuchiya Taketsugu, Kozuki Amane, Iida Osamu

Сравнительное исследованиеСтатьяМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

PURPOSE: To compare primary patency between MISAGO (Terumo Corporation, Tokyo, Japan) and S.M.A.R.T. CONTROL (Cordis Corporation, Miami Lakes, Florida), second-generation and first-generation nitinol stents, in femoropopliteal lesions.

MATERIALS AND

METHODS

This multicenter, retrospective study included 240 cases with MISAGO stent implantation and 1,265 cases with S.M.A.R.T. stent implantation. The S.M.A.R.T. group had more Trans-Atlantic Inter-Society of Consensus (TASC) II class C/D lesions (53% vs 41%, P = .001) and smaller reference vessel diameter (RVD) (5.3 mm ± 0.9 vs 5.5 mm ± 0.9, P < .001).

RESULTS

Kaplan-Meier estimates of 2-year primary patency after S.M.A.R.T. and MISAGO stent implantation were 67% and 55% (P = .007). Interaction analysis revealed that TASC II classification and RVD had a significant influence on the association of MISAGO versus S.M.A.R.T. stents with the outcome. The study population was stratified according to TASC II classification and RVD, and MISAGO and S.M.A.R.T. stents were compared after propensity score matching. There was no significant difference in 2-year patency between the 2 stents in the subgroup with TASC II class A/B and RVD ≥ 5 mm (S.M.A.R.T. 82% ± 4 vs MISAGO 74% ± 5, P = .480). MISAGO stents had lower primary patency than S.M.A.R.T. stents in cases with TASC II class C/D or RVD < 5 mm (S.M.A.R.T. 62% ± 6 vs MISAGO 25% ± 6, P = .015).

CONCLUSIONS

S.M.A.R.T. and MISAGO stents had similar patency in simple lesions, but MISAGO stents had lower patency than S.M.A.R.T. stents in more complex lesions.

Для цитирования: Suzuki Kenji, Takahara Mitsuyoshi, Shintani Yoshiaki, Tanaka Akiko, Soga Yoshimitsu, Yamaoka Terutoshi, Tosaka Atsushi, Sasaki Shinya, Kawasaki Daizo, Tsuchiya Taketsugu, Kozuki Amane, Iida Osamu. Retrospective Multicenter Comparison of S.M.A.R.T. CONTROL and MISAGO Stents in Treatment of Femoropopliteal Lesions.. Journal of vascular and interventional radiology : JVIR. 2016. DOI: 10.1016/j.jvir.2016.05.042.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.