MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/biot.201500037

Медицинская библиотека · Biotechnology journal · 2015

Determination of antibiotic EC50 using a zero-flow microfluidic chip based growth phenotype assay.

Dai Jing, Suh Sang-Jin, Hamon Morgan, Hong Jong Wook

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПоддержка правительства СШАПеревод пока не подготовлен

Аннотация

Current existing assay systems for evaluating antimicrobial activity suffer from several limitations including excess reagent consumption and inaccurate concentration gradient preparation. Recently, microfluidic systems have been developed to provide miniaturized platforms for antimicrobial susceptibility assays. However, some of current microfluidic based assays require continuous flows of reagents or elaborate preparation steps during concentration preparation. In this study, we introduce a novel microfluidic chip based growth phenotype assay that automatically generates a logarithmic concentration gradient and allows observing the growth of pathogenic bacteria under different concentrations of antibiotics in nanoliter batch culture reactors. We chose pathogen bacterium Pseudomonas aeruginosa as a model strain and evaluated the inhibitory effects of gentamicin and ciprofloxacin. We determined the EC50 values and confirmed the validity of the present system by comparing the EC50 values obtained through conventional test tube method. We demonstrated that the EC50 values acquired from present assay are comparable to those obtained from conventional test tube cultures. The potential application of present assay system for investigating combinatorial effects of antibiotics on multidrug resistant pathogenic bacteria is discussed and it can be further used for systematic evaluation of antifungal or antiviral agents.

Для цитирования: Dai Jing, Suh Sang-Jin, Hamon Morgan, Hong Jong Wook. Determination of antibiotic EC50 using a zero-flow microfluidic chip based growth phenotype assay.. Biotechnology journal. 2015. DOI: 10.1002/biot.201500037.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.