MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.cmpb.2016.03.005

Медицинская библиотека · Computer methods and programs in biomedicine · 2016

A novel method of artery stenosis diagnosis using transfer function and support vector machine based on transmission line model: A numerical simulation and validation study.

Xiao Hanguang, Avolio Alberto, Huang Decai

СтатьяПоддержка исследования: вне правительства СШАВалидационное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND AND

OBJECTIVE

Transfer function (TF) is an important parameter for the analysis and understanding of hemodynamics when arterial stenosis exists in human arterial tree. Aimed to validate the feasibility of using TF to diagnose arterial stenosis, the forward problem and inverse problem were simulated and discussed.

METHODS

A calculation method of TF between ascending aorta and any other artery was proposed based on a 55 segment transmission line model (TLM) of human artery tree. The effects of artery stenosis on TF were studied in two aspects: stenosis degree and position. The degree of arterial stenosis was specified to be 10-90% in three representative arteries: carotid, aorta and iliac artery, respectively. In order to validate the feasibility of diagnosis of artery stenosis using TF and support vector machine (SVM), a database of TF was established to simulate the real conditions of artery stenosis based on the TLM model. And a diagnosis model of artery stenosis was built by using SVM and the database.

RESULTS

The simulating results showed the modulus and phase of TF were decreasing sharply from frequency 2 to 10Hz with the stenosis degree increasing and displayed their unique and nonlinear characteristics when frequency is higher than 10Hz. The diagnosis results showed the average accuracy was above 76% for the stenosis from 10% to 90% degree, and the diagnosis accuracies of moderate (50%) and serious (90%) stenosis were 87% and 99%, respectively. When the stenosis degree increased to 90%, the accuracy of stenosis localization reached up to 94% for most of arteries.

CONCLUSIONS

The proposed method of combining TF and SVM is a theoretically feasible method for diagnosis of artery stenosis.

Для цитирования: Xiao Hanguang, Avolio Alberto, Huang Decai. A novel method of artery stenosis diagnosis using transfer function and support vector machine based on transmission line model: A numerical simulation and validation study.. Computer methods and programs in biomedicine. 2016. DOI: 10.1016/j.cmpb.2016.03.005.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.