MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1136/bmjinnov-2021-000864

Медицинская библиотека · BMJ innovations · 2022

Real-time continuous measurement of lactate through a minimally invasive microneedle patch: a phase I clinical study.

Ming Damien K, Jangam Saylee, Gowers Sally An, Wilson Richard, Freeman David Me, Boutelle Martyn G, Cass Anthony Eg, O'Hare Danny, Holmes Alison H

СтатьяПеревод пока не подготовлен

Аннотация

INTRODUCTION

Determination of blood lactate levels supports decision-making in a range of medical conditions. Invasive blood-sampling and laboratory access are often required, and measurements provide a static profile at each instance. We conducted a phase I clinical study validating performance of a microneedle patch for minimally invasive, continuous lactate measurement in healthy volunteers.

METHODS

Five healthy adult participants wore a solid microneedle biosensor patch on their forearms and undertook aerobic exercise for 30 min. The microneedle biosensor quantifies lactate concentrations in interstitial fluid within the dermis continuously and in real-time. Outputs were captured as sensor current and compared with lactate concentrations from venous blood and microdialysis.

RESULTS

The biosensor was well-tolerated. Participants generated a median peak venous lactate of 9.25 mmol/L (IQR 6.73-10.71).Microdialysate concentrations of lactate closely correlated with blood. Microneedle biosensor current followed venous lactate concentrations and dynamics, with good agreement seen in all participants. There was an estimated lag-time of 5 min (IQR -4 to 11 min) between microneedle and blood lactate measurements.

CONCLUSION

This study provides first-in-human data on use of a minimally invasive microneedle patch for continuous lactate measurement, providing dynamic monitoring. This low-cost platform offers distinct advantages to frequent blood sampling in a wide range of clinical settings, especially where access to laboratory services is limited or blood sampling is infeasible. Implementation of this technology in healthcare settings could support personalised decision-making in a variety of hospital and community settings.

TRIAL REGISTRATION NUMBER: NCT04238611.

Для цитирования: Ming Damien K, Jangam Saylee, Gowers Sally An, Wilson Richard, Freeman David Me, Boutelle Martyn G, Cass Anthony Eg, O'Hare Danny, Holmes Alison H. Real-time continuous measurement of lactate through a minimally invasive microneedle patch: a phase I clinical study.. BMJ innovations. 2022. DOI: 10.1136/bmjinnov-2021-000864.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.