The use of freeze-dried blood samples affects the results of a dried blood spot analysis.

Francke Marith I, van Domburg Bart, van de Velde Daan, Hesselink Dennis A, de Winter Brenda C M

СтатьяПеревод пока не подготовлен

Аннотация

Dried blood spot (DBS) microsampling has several advantages over venous blood sampling. In a clinical validation study of tacrolimus microsampling it was noted that tacrolimus DBS concentrations ([Tac]DBS) were systematically higher than tacrolimus whole-blood concentrations ([Tac]WB). This observation was explored by investigating the effect of using freeze-dried standards (STFD) for [Tac]DBS measurement. For all experiments, both non-frozen whole-blood samples and whole-blood samples that were frozen and thawed (to simulate freeze-drying) of 10 patients were analyzed. Multiple tacrolimus concentrations were measured: 1) [Tac]WB, 2) [Tac]DBS, where 15 μL was volumetrically applied to a pre-punched DBS disk, and 3) [Tac]DBS, where 50 μL was applied before a 6 mm DBS disk was punched from the card. All tacrolimus concentrations were determined independently using STFD and standards made of non-frozen blood spiked with tacrolimus (STSP). In both non-frozen and frozen and thawed whole-blood samples, [Tac]WB measured with STFD appeared similar to [Tac]WB measured with STSP (Ratios 1.061 and 1.077, respectively). In non-frozen samples, the median ratio between the [Tac]DBS measured with STFD, and [Tac]WB measured with STFD (the reference method), was 1.396. When blood was volumetrically applied to the DBS card (to eliminate the effect of the spreading over the filter paper), this ratio was 1.009. In conclusion, when using DBS microsampling to quantify concentrations of analytes, one should be aware that using the commercially available freeze-dried blood samples for the preparation of standards may affect the spreading of blood on the filter-paper, leading to a systematic error in the results.

Для цитирования: Francke Marith I, van Domburg Bart, van de Velde Daan, Hesselink Dennis A, de Winter Brenda C M. The use of freeze-dried blood samples affects the results of a dried blood spot analysis.. Clinical biochemistry. 2022. DOI: 10.1016/j.clinbiochem.2022.03.007.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.