BACKGROUND

Angio-based microvascular resistance (AMR) was proposed as a tool to quantitatively assess coronary microvascular based on single angiographic projection. The aims of this study are to assess the diagnostic accuracy and prognostic significance of AMR in ST-segment elevation myocardial infarction (STEMI) patients.

METHODS

AMR was measured (Of these, 22 patients measured index of microvascular resistance (IMR)) in 70 STEMI patients after primary percutaneous coronary intervention (pPCI). ST-segment resolution (STR) was assessed 2 h after pPCI simultaneously. Transthoracic echocardiography was performed within 1 day and approximately 1 year after pPCI. STEMI patients underwent pPCI were followed up for 7.3 years and the primary endpoint was the major adverse cardiac and cerebral events (MACCEs).

RESULTS

AMR showed significant correlations with IMR (R = 0.334, P = 0.005). AMR has good predictive power for STR after pPCI (area under the curve: 0.889, sensitivity: 94.59%, specificity: 75.76%) in receiver operating characteristic (ROC) curve. Low-AMR patients showed markedly improved left ventricular ejection fraction (LVEF) 1 year after pPCI (42(40-49) vs. 41(39-44), P = 0.041). High-AMR patients showed higher risk for MACCEs than those with Low-AMR (HR = 3.90, P = 0.02). In multivariate cox regression analysis, AMR was considered an independent predictor of MACCEs (HR: 1.153, P = 0.020).

CONCLUSIONS

AMR is a reliable tool for the estimation of microvascular resistance and prognosis in the absence of intracoronary pressure-temperature sensor wire and adenosine based on single angiographic projection.

Для цитирования: Zhang Zhe, Dai Qing, Zhang Xinlin, Qiao Shiyang, Bao Xue, Wang Kun, Xue Peng, Gao Yuan, Guo Xuemei, Xue Yanan, Wei Zhonghai, Xu Biao, Kang Lina. Microcirculatory resistance based on a single angiographic view in ST-segment elevation myocardial infarction patients.. BMC cardiovascular disorders. 2025. DOI: 10.1186/s12872-025-04796-4.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.