Evaluation of treatment response to enzyme replacement therapy with Velaglucerase alfa in patients with Gaucher disease using whole-body magnetic resonance imaging.

Laudemann K, Moos L, Mengel E, Lollert A, Hoffmann C, Brixius-Huth M, Wagner D, Düber C, Staatz G

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

This was a retrospective data analysis to evaluate the treatment response to enzyme replacement therapy (ERT) with Velaglucerase alfa using whole-body magnetic resonance imaging (MRI).

MATERIALS AND

METHODS

A baseline and follow-up MRI were performed on 18 Gaucher Type 1 patients at an interval of 11.6 months. The MRI score systems determined the Bone-Marrow-Burden (BMB) score, the Düsseldorf-Gaucher score (DGS), and the Vertebra-Disc-Ratio (VDR). The Severity Score Index Type 1 (GD-DS3) was also assessed.

RESULTS

The baseline MRI medians were: BMB, 7.00; DGS, 3.00; and VDR: 1.70; while, the follow-up MRI medians were: BMB, 7.00; DGS, 3.00; and VDR: 1.73. The baseline GD-DS3 median was 2.40 (BMB excl.: 0.50) and the follow-up median was 2.00 (BMB excl.: 0.50). There was weak statistical significance with the Wilcoxon signed-rank test for the DGS (p=0.034) and GD-DS3 (p=0.047) between both MRIs.

CONCLUSION

Velaglucerase alfa therapy is a effective long-term treatment for Gaucher Type 1 patients who are newly diagnosed or switching therapies. Measurements with whole-body MRI and an objective scoring system were reliable tools for detecting early stage bone marrow activity. Further research is needed to evaluate the "Booster-Effect" of Velaglucerase alfa therapy in Gaucher skeletal disease.

Для цитирования: Laudemann K, Moos L, Mengel E, Lollert A, Hoffmann C, Brixius-Huth M, Wagner D, Düber C, Staatz G. Evaluation of treatment response to enzyme replacement therapy with Velaglucerase alfa in patients with Gaucher disease using whole-body magnetic resonance imaging.. Blood cells, molecules & diseases. 2015. DOI: 10.1016/j.bcmd.2015.11.003.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.