MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1136/rmdopen-2026-007207

Медицинская библиотека · RMD open · 2026

Comparative analysis of instruments measuring peripheral arthritis activity in Spondyloarthritis: a measurement properties study in 13 RCTs.

Capelusnik Dafne, López-Medina Clementina, Webers Casper, Ortolan Augusta, van der Heijde Désirée, Landewé Robert, Mease Philip J, Molto Anna, Ramiro Sofia

СтатьяСравнительное исследованиеПеревод в очереди

Аннотация

OBJECTIVES

Using randomised controlled trial (RCT) data, this study evaluated the measurement properties of selected instruments to assess peripheral arthritis in axial and peripheral spondyloarthritis (axSpA/pSpA) and to inform selection of the best-performing instrument.

METHODS

Eligible studies were RCTs in axSpA or pSpA with individual patient data available to calculate Patient Global Assessment (PGA), swollen/tender joint counts (44 or 66/68 joints), C reactive protein, Bath Ankylosing Spondylitis Disease Activity Index (BASDAI), Axial Spondyloarthritis Disease Activity Score, Disease Activity Index for Psoriatic Arthritis/Disease Activity in Psoriatic Arthritis with 44 joint count (DAPSA44) and 44-joint Disease Activity Score at baseline and timing of primary endpoint. In axSpA, analyses were restricted to patients with peripheral arthritis at baseline. Measurement properties assessed included construct validity, test-retest reliability, longitudinal construct validity, trial discrimination and thresholds of meaning. Risk of bias (RoB) was evaluated and evidence was synthesised using Outcome Measures in Rheumatology-based GREEN/AMBER/RED ratings (low/uncertain/high RoB and good/adequate/poor performance, respectively).

RESULTS

13 RCTs were included (10 axSpA and 3 pSpA). In axSpA trials, 25-51% of patients had peripheral arthritis at baseline (median swollen joint count of 44 joints (SJC44) across studies: 2-3); in pSpA trials, median SJC44 ranged 2-5. In axSpA, construct validity and thresholds of meaning were rated AMBER/GREEN for all instruments, while test-retest reliability was RED only for PGA. Responsiveness was consistently GREEN. Clinical trial discrimination was RED for single-item instruments but consistently GREEN for composite scores. In pSpA, most instruments showed AMBER/GREEN performance, although SJC44 demonstrated RED discrimination.

CONCLUSIONS

This study provides the first comprehensive, trial-based evaluation of measurement properties for instruments assessing peripheral arthritis activity in axSpA and pSpA. Composite scores, such as BASDAI, ASDAS and DAPSA44, generally demonstrated more robust performance than single-item instruments, expanding the evidence base for the final instrument-selection phase.

Для цитирования: Capelusnik Dafne, López-Medina Clementina, Webers Casper, Ortolan Augusta, van der Heijde Désirée, Landewé Robert, Mease Philip J, Molto Anna, Ramiro Sofia. Comparative analysis of instruments measuring peripheral arthritis activity in Spondyloarthritis: a measurement properties study in 13 RCTs.. RMD open. 2026. DOI: 10.1136/rmdopen-2026-007207.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.