MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1183/13993003.00651-2017

Медицинская библиотека · The European respiratory journal · 2017

Blood pressure response to CPAP treatment in subjects with obstructive sleep apnoea: the predictive value of 24-h ambulatory blood pressure monitoring.

Castro-Grattoni Anabel L, Torres Gerard, Martínez-Alonso Montserrat, Barbé Ferran, Turino Cecilia, Sánchez-de-la-Torre Alicia, Cortijo Anunciacion, Duran-Cantolla Joaquin, Egea Carlos, Cao Gonzalo, Sánchez-de-la-Torre Manuel

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

The reduction in blood pressure (BP) with continuous positive airway pressure (CPAP) is modest and highly variable. In this study, we identified the variables that predict BP response to CPAP.24-h ambulatory BP monitoring (ABPM), C-reactive protein (CRP), leptin, adiponectin and 24-h urinary catecholamine were measured before and after 6 months of CPAP in obstructive sleep apnoea (OSA) patients.Overall, 88 middle-aged, obese male patients with severe OSA (median apnoea-hypopnoea index 42 events·h-1) were included; 28.4% had hypertension. 62 patients finished the study, and 60 were analysed. The daytime diastolic BP (-2 mmHg) and norepinephrine (-109.5 nmol·day-1) were reduced after CPAP, but no changes in the 24-h BP, night-time BP, dopamine, epinephrine, CRP, leptin or adiponectin were detected. The nocturnal normotension was associated with an increased night-time-BP (+4 mmHg) after CPAP, whereas nocturnal hypertension was associated with a reduction of 24-h BP (-3 mmHg). A multivariate linear regression model showed differential night-time BP changes after CPAP. Specifically, low night-time heart rate (<68 bpm) and BP dipper profile were associated with increased night-time BP and new diagnosis of nocturnal hypertension.Our results suggest that nocturnal hypertension, circadian BP pattern and night-time heart rate could be clinical predictors of BP response to CPAP and support the usefulness of 24-h ABPM for OSA patients before treatment initiation. These results need to be confirmed in further studies.

Для цитирования: Castro-Grattoni Anabel L, Torres Gerard, Martínez-Alonso Montserrat, Barbé Ferran, Turino Cecilia, Sánchez-de-la-Torre Alicia, Cortijo Anunciacion, Duran-Cantolla Joaquin, Egea Carlos, Cao Gonzalo, Sánchez-de-la-Torre Manuel. Blood pressure response to CPAP treatment in subjects with obstructive sleep apnoea: the predictive value of 24-h ambulatory blood pressure monitoring.. The European respiratory journal. 2017. DOI: 10.1183/13993003.00651-2017.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.