MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/jce.15122

Медицинская библиотека · Journal of cardiovascular electrophysiology · 2021

Psychometric evaluation of the implantable cardioverter defibrillator body image concerns questionnaire (ICD-BICQ).

Frydensberg Vivi Skibdal, Johansen Jens Brock, Möller Sören, Strömberg Anna, Pedersen Susanne S

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Patients receiving an implantable cardioverter defibrillator (ICD) generally adapt well to living with their device, but we know little about the prevalence of patients' body image concerns (BICs) postimplant.

METHODS

The objectives were to evaluate the psychometric properties of the ICD-body image concerns questionnaire (BICQ), find a cut-off indicating BICs and determine the prevalence of BICs. Construct validity was determined using the Kaiser-Meyer-Olkin test, Scree-plot and explorative factor analysis. Internal consistency was examined via Cronbach's alpha. Correlations to other validated questionnaires, a weighted and simple scale and a cut-off indicating BICs was evaluated.

RESULTS

In total, 331 patients completed the 39-item ICD-BICQ together with: Type D Scale (DS14), Generalized Anxiety Disorder scale (GAD-7), Patient Health Questionnaire (PHQ-9), and Florida Patient Acceptance Survey. Five patients were excluded due to reoperations, leaving 326 patients in the analyses. Results revealed a one-factor structure with 32 items and Cronbach's alpha at .948. A cut-off at 36 points displayed the 20% patients with the highest score of BICs. The prevalence was 29.8% in women and 18.4% in men.

CONCLUSION

The psychometric evaluation of the 32-item ICD-BICQ showed acceptable construct validity and internal reliability. We recommend a cut-off score at 36 points to identify patients at risk of having BICs. The prevalence of BICs indicated that both men and women are at risk of having BICs. The ICD-BICQ can be used in clinical practice to help healthcare professionals to identify patients at risk of BICs and as to evaluate BICs when implementing new operation techniques.

Для цитирования: Frydensberg Vivi Skibdal, Johansen Jens Brock, Möller Sören, Strömberg Anna, Pedersen Susanne S. Psychometric evaluation of the implantable cardioverter defibrillator body image concerns questionnaire (ICD-BICQ).. Journal of cardiovascular electrophysiology. 2021. DOI: 10.1111/jce.15122.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.