DOI 10.1111/j.1532-5415.2011.03352.x
Continuous noninvasive orthostatic blood pressure measurements and their relationship with orthostatic intolerance, falls, and frailty in older people.
Аннотация
OBJECTIVES
To identify morphological orthostatic blood pressure (BP) phenotypes in older people and assess their correlation with orthostatic intolerance (OI), falls, and frailty and to compare the discriminatory performance of a morphological classification with two established orthostatic hypotension (OH) definitions: consensus (COH) and initial (IOH).
DESIGN
Cross-sectional.
SETTING
Geriatric research clinic.
PARTICIPANTS
Four hundred forty-two participants (mean age 72, 72% female) without dementia or risk factors for autonomic neuropathy.
MEASUREMENTS: Active lying-to-standing test monitored using a continuous noninvasive BP monitor. For the morphological classification, four orthostatic systolic BP variables were extracted (delta (baseline - nadir) and maximum percentage of baseline recovered by 30 seconds and 1 and 2 minutes) using the 5-second averages method and entered in K-means cluster analysis (three clusters). Main outcomes were OI, falls (≥1 in past 6 months), and frailty (modified Fried criteria).
RESULTS
The morphological clusters were small drop, fast overrecovery (n=112); medium drop, slow recovery (n=238); and large drop, nonrecovery (n=92). Their characterization revealed an increasing OI gradient (17.9%, 27.5%, and 44.6% respectively, P<.001) but no significant gradients in falls or frailty. The COH definition failed to reveal clinical differences between COH+ (n=416) and COH- (n=26) participants. The IOH definition resulted in a clinically meaningful separation between IOH+ (n=85) and IOH- (n=357) subgroups, as assessed according to OI (100% vs 11.5%, P<.001), falls (24.7% vs 10.4%, P<.001), and frailty (14.1% vs 5.4%, P=.005).
CONCLUSION
It is recommended that the IOH definition be applied when taking continuous noninvasive orthostatic BP measurements in older people.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.