MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ijcard.2021.04.068

Медицинская библиотека · International journal of cardiology · 2021

Aortic valve replacement vs. balloon-expandable and self-expandable transcatheter implantation: A network meta-analysis.

D'Ascenzo Fabrizio, Bruno Francesco, Baldetti Luca, De Filippo Ovidio, Marengo Giorgio, Breviario Susanna, Melillo Francesco, Thyregod Hans Gustav Hørsted, Thiele Holger, Sondergaard Lars, Popma Jeffrey J, Kodali Susheel, Franchin Luca, Annaratone Margherita, Marruncheddu Laura, Gallone Guglielmo, Crimi Gabriele, La Torre Michele, Rinaldi Mauro, Omedè Pierluigi, Conrotto Federico, Salizzoni Stefano, De Ferrari Gaetano Maria

СтатьяNetwork Meta-AnalysisПеревод пока не подготовлен

Аннотация

INTRODUCTION

Recently, observational data have raised concerns about safety of selfexpandable (SE) compared to balloon-expandable (BE) valves in TAVI, although potentially limited by patient selection bias.

METHODS

All Randomized Controlled Trials (RCTs) comparing BE vs. SE TAVI or/and vs. aortic valve replacement (AVR) were included and compared through Network Meta Analysis (NMA). All-cause and cardiovascular (CV) mortality were the primary endpoints, stroke, rates of permanent pacemaker implantation (PPI), moderate/severe paravalvular leak (PVL) and reintervention were the secondary endpoints. Results We obtained data from 11 RCTs, encompassing 9752 patients. After one and two years, no significant differences for allcause and CV mortality were observed. Compared to surgical bioprostheses, both BE and SE TAVI reduced the risk of acute kidney injury (OR 0.42; CI 95% 0.30-0.60 and OR 0.44; CI 95% 0.32-0.60), new-onset atrial fibrillation (OR 0.24; CI 95% 0.14-0.42 and OR 0.21; CI 95% 0.13-0.34) and major bleedings (OR 0.32; CI 95% 0.16-0.65 and OR 0.47; CI 95% 0.25-0.89). The BE prostheses reduced the risk of moderate/severe PVL at 30-day (OR 0.31; CI 95% 0.17-0.55) and of PPI both at 30-day (OR 0.51; CI 95% 0.33-0.79) and 1 year (OR 0.40; CI 95% 0.30-0.55) as compared to SE TAVI. Conclusions A TAVI strategy, independently from BE or SE prostheses, offers a midterm survival comparable to AVR. The BE prostheses are associated with a reduction of PPI and PVL compared to SE prostheses without any differences in all-cause and CV mortality during two years of follow up. PROSPERO ID CRD42020182407.

Для цитирования: D'Ascenzo Fabrizio, Bruno Francesco, Baldetti Luca, De Filippo Ovidio, Marengo Giorgio, Breviario Susanna, Melillo Francesco, Thyregod Hans Gustav Hørsted, Thiele Holger, Sondergaard Lars, Popma Jeffrey J, Kodali Susheel, Franchin Luca, Annaratone Margherita, Marruncheddu Laura, Gallone Guglielmo, Crimi Gabriele, La Torre Michele, Rinaldi Mauro, Omedè Pierluigi, Conrotto Federico, Salizzoni Stefano, De Ferrari Gaetano Maria. Aortic valve replacement vs. balloon-expandable and self-expandable transcatheter implantation: A network meta-analysis.. International journal of cardiology. 2021. DOI: 10.1016/j.ijcard.2021.04.068.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.