MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/jce.14885

Медицинская библиотека · Journal of cardiovascular electrophysiology · 2021

Half-normal saline versus normal saline for irrigation of open-irrigated radiofrequency catheters in atrial fibrillation ablation.

Gianni Carola, Gallinghouse G Joseph, Al-Ahmad Amin, Horton Rodney P, Bailey Shane M, Burkhardt J David, Bassiouny Mohamed A, MacDonald Bryan C, Quintero Mayedo Angel, Della Rocca Domenico G, Mohanty Sanghamitra, Trivedi Chintan, Di Biase Luigi, Hranitzky Patrick M, Sanchez Javier E, Natale Andrea

СтатьяРандомизированное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

The creation of effective and permanent lesions is a crucial factor in determining the success rate of atrial fibrillation (AF) ablation. By increasing the efficacy of radiofrequency (RF) energy-mediated lesion formation, half-normal saline (HNS) as an irrigant for open-irrigated ablation catheters has the potential to reduce procedural times and improve acute and long-term outcomes.

METHODS

This is a double-blind randomized clinical trial of 99 patients undergoing first-time RF catheter ablation for AF. Patients enrolled were randomly assigned in a 1:1 fashion to perform ablation using HNS or normal saline (NS) as an irrigant for the ablation catheter.

RESULTS

The use of HNS is associated with shorter RF times (26 vs. 33 min; p = .02) with comparable procedure times (104 vs. 104 min). The rate of acute pulmonary vein reconnections (16% vs. 18%) was comparable, with a median of 1 vein reconnection in the HNS arm versus 2 in the NS arm. There was no difference in procedure-related complications, including the incidence of postprocedural hyponatremia when using HNS. Over the 1-year follow-up, there is no significant difference between the HNS and NS with respect to the recurrence of any atrial arrhythmia (off antiarrhythmic drugs [AAD]: 47% vs. 52%; hazard ratio [HR]: 1.17, 95% confidence interval [CI]: 0.66-2.06; off/on AAD: 66% vs. 66%, HR: 1.06, 95% CI: 0.53-2.12), with a potential benefit of using HNS when considering the paroxysmal AF cohort (on/off AAD 73% vs. 62%, HR: 0.72, 95% CI: 0.19-2.70).

CONCLUSIONS

In a mixed cohort of patients undergoing first-time AF ablation, irrigation of open-irrigated RF ablation catheters with HNS is associated with shorter RF times, with a comparably low rate of procedure-related complications. In the long term, there is no significant difference with respect to the recurrence of any atrial arrhythmia. Larger studies with a more homogeneous population are necessary to determine whether HNS improves clinical outcomes.

Для цитирования: Gianni Carola, Gallinghouse G Joseph, Al-Ahmad Amin, Horton Rodney P, Bailey Shane M, Burkhardt J David, Bassiouny Mohamed A, MacDonald Bryan C, Quintero Mayedo Angel, Della Rocca Domenico G, Mohanty Sanghamitra, Trivedi Chintan, Di Biase Luigi, Hranitzky Patrick M, Sanchez Javier E, Natale Andrea. Half-normal saline versus normal saline for irrigation of open-irrigated radiofrequency catheters in atrial fibrillation ablation.. Journal of cardiovascular electrophysiology. 2021. DOI: 10.1111/jce.14885.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.