DOI 10.1371/journal.pone.0240860
Clinical impact of angiographically insignificant suboptimal poststent findings detected by optical coherence tomography after drug-eluting stent implantation.
Аннотация
BACKGROUND
Although optical coherence tomography (OCT)-detected suboptimal findings (SF-OCT) such as malapposition, edge dissection, tissue protrusion, thrombus and small minimal stent area (MSA) are frequently observed after the implantation of drug-eluting stents (DES), their clinical implications are controversial.
HYPOTHESIS: Clinical outcomes may differ between patients with SF-OCTs and without SF-OCTs after DES implantation.
METHODS
A total of 576 patients undergoing OCT analysis after DES implantation were divided into SF-OCT group (n = 379, 379 lesions) and No SF-OCT group (n = 197, 197 lesions). The study population had no significant abnormal finding in final angiography. Quantification was performed for each SF-OCT. The incidences of major adverse cardiovascular events (MACE: all-cause death, non-fatal myocardial infarction, target vessel revascularization, and stent thrombosis) were compared between the two groups. A median follow-up duration was 21.5 months.
RESULTS
Among 379 patients with SF-OCT, 32.4% had multiple SF-OCTs. Malapposition (32.1%, IQR of maximal depth 315-580 μm) was the most frequent, followed by small MSA (31.6%), edge dissection (12.5%, IQR of maximal flap of opening 0.27-0.52 mm), thrombus (7.6%, IQR of diameter 1.31-1.97mm) and tissue protrusion (6.8%, IQR of diameter 1.05-1.67 mm). The SF-OCT group showed smaller stent diameter and longer stent length, and lower in-stent lumen expansion rate. The incidence of MACE did not differ between the two groups (3.0% for No SF-OCT vs. 5.0% for SF-OCT; HR 1.601; 95% CI 0.639 to 4.011; P = 0.310).
CONCLUSIONS
The presence of angiographically insignificant SF-OCTs were not associated with clinical outcomes in this study.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.