MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.nut.2018.09.035

Медицинская библиотека · Nutrition (Burbank, Los Angeles County, Calif.) · 2018

Body composition measurement by air displacement plethysmography in pregnancy: Comparison of predicted versus measured thoracic gas volume.

Pellonperä Outi, Koivuniemi Ella, Vahlberg Tero, Mokkala Kati, Tertti Kristiina, Rönnemaa Tapani, Laitinen Kirsi

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVES

Body composition measurements with air displacement plethysmography (ADP) define body volume, which must be corrected for thoracic gas volume (TGV). We hypothesized that physiologic changes owing to pregnancy could affect the accuracy of predicted TGV and introduce errors into body composition measurements.

METHODS

We investigated the effect of measuring versus predicting TGV on the accuracy of body composition calculations measured with ADP in overweight and obese pregnant women. The fat and fat-free masses of 110 women were determined with ADP with predicted and measured TGV.

RESULTS

Measured TGV decreased from early to late pregnancy (P = 0.0002). Compared with measured TGV, predicted TGV was 6.3% higher during early gestation and 12.6% higher during late gestation (both P ≤ 0.001). The use of predicted instead of measured TGV in body composition calculations resulted in an overestimation of fat mass by 0.8% during the early stage, and 2.6% during the late stage of pregnancy (both P ≤ 0.001).

CONCLUSIONS

Measuring TGV increases the accuracy of body composition measurement by ADP in overweight and obese women, particularly during the late stage of pregnancy.

Для цитирования: Pellonperä Outi, Koivuniemi Ella, Vahlberg Tero, Mokkala Kati, Tertti Kristiina, Rönnemaa Tapani, Laitinen Kirsi. Body composition measurement by air displacement plethysmography in pregnancy: Comparison of predicted versus measured thoracic gas volume.. Nutrition (Burbank, Los Angeles County, Calif.). 2018. DOI: 10.1016/j.nut.2018.09.035.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.