MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/mca.0000000000000949

Медицинская библиотека · Coronary artery disease · 2021

Ultrathin biodegradable polymer sirolimus-eluting stent versus contemporary durable polymer everolimus-eluting stent for percutaneous coronary intervention: a meta-analysis of randomized trials.

Sethi Ankur, Kodumuri Vamsi, Prasad Vinoy, Kassotis John

СтатьяМетаанализПеревод пока не подготовлен

Аннотация

INTRODUCTION

Improvements in coronary drug-eluting stent technology has focused on reducing the long-term complications associated with the effects of the residual footprint on the vessel wall. Although many of the newer stents have exhibited noninferiority to the durable polymer everolimus-eluting stent (DP-EES), they have yet to exhibit clear superiority. We compared the performance of the latest ultrathin strut biodegradable polymer sirolimus-eluting stents (BP-SES) to DP-EES.

METHODS

We searched the electronic databases for randomized controlled trials comparing BP-SES to DP-EES. A random effect meta-analysis was performed using the Poisson regression model. The primary end point was target lesion failure (TLF), a composite of target vessel myocardial infarction (TVMI), cardiac death and target lesion revascularization (TLR).

RESULTS

There was no difference between the stents in stent thrombosis [incidence rate ratio (IRR) = 0.79, 95% confidence interval (CI) 0.58-1.06), TLR (IRR = 0.88, 95% CI 0.57-1.38), TVMI (IRR = 0.79, 95% CI 0.61-1.01), cardiac death (IRR = 0.99, 95% CI 0.76-1.29) and target vessel failure (IRR = 0.82, 95% CI 0.64-1.06). In addition, there was no difference in TLF (IRR = 0.82, 95% CI 0.64-1.06). There was evidence of reduced TLF in small vessels with BP-SES based on definition used (defined as ≤2.75 mm; IRR 0.64, 95% CI 0.46-0.91 versus ≤3 mm; IRR 1.11, 95% CI 0.90-1.36).

CONCLUSION

In our study, the performance of the latest generation BP-SES was comparable to DP-EES but failed to show superiority. The possible benefit in patients with small vessels should be explored future trials.

Для цитирования: Sethi Ankur, Kodumuri Vamsi, Prasad Vinoy, Kassotis John. Ultrathin biodegradable polymer sirolimus-eluting stent versus contemporary durable polymer everolimus-eluting stent for percutaneous coronary intervention: a meta-analysis of randomized trials.. Coronary artery disease. 2021. DOI: 10.1097/mca.0000000000000949.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.