DOI 10.1007/s12350-018-01557-z
Head-to-head comparison of the diagnostic performances of Rubidium-PET and SPECT with CZT camera for the detection of myocardial ischemia in a population of women and overweight individuals.
Аннотация
BACKGROUND
The aim of this study was to compare the diagnostic performances for the detection of myocardial ischemia of 82-Rb-PET-MPS and 99m-Tc-SPECT-MPS in overweight individuals and women.
METHODS AND
RESULTS
Men with BMI ≥ 25 and women referred for MPS were considered for inclusion. All individuals underwent 99m-Tc-SPECT-MPS with CZT cameras and 82-Rb-PET-MPS in 3D-mode. Individuals with at least one positive MPS were referred for coronary angiography (CA) with FFR measurements. A criterion for positivity was a composite endpoint including significant stenosis on CA or, in the absence of CA, the occurrence of acute coronary event during the following year. 313 patients (46% women) with mean BMI of 31.8 ± 6.5 were included. Sensitivity for the detection of myocardial ischemia was higher with 82-Rb-PET-MPS compared with 99m-Tc-SPECT-MPS (85% vs. 57%, P < .05); specificity was equally high with both imaging techniques (93% vs. 94%, P > .05). 82-Rb-PET allowed for a more accurate detection of patients with a high-risk coronary artery disease (HR-CAD) than 99m-Tc-SPECT-MPS (AUC = 0.86 vs. 0.75, respectively; P = .04).
CONCLUSIONS
In women and overweight individuals, 82-Rb-PET-MPS provides higher sensitivity for the detection of myocardial ischemia than 99m-Tc-SPECT-MPS thanks to a better image quality and an improved detection of HR-CAD.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.