DOI 10.2174/157016208785132509
Proven intra and interobserver reliability in the echographic assessments of body fat changes related to HIV associated Adipose Redistribution Syndrome (HARS).
Аннотация
OBJECTIVE
To prove intra- and inter-observer's reliability of ultrasound (US) in the assessment of lipoatrophic findings related to the HIV associated Adipose Redistribution Syndrome (HARS).
PATIENTS AND
METHODS
In two separated sessions, 2 consecutive measurements of subcutaneous fat thickness (SFT) were performed by each observer at the deepest point of Bichat pad, the dorsal face of arm and the mid thigh for the assessment of facial, brachial and crural lipoatrophy, respectively. We enrolled 20 HIV patients, rotating an experienced and untrained sonologist. The assessments were performed avoiding any stand off pads in the skin and excluding artefacts due to the too abundant quantity of gel to obtaining, with minimal transducer pressure, the best resolution of the reference points.
RESULTS
Means of facial, brachial and crural SFT showed no significant differences between the workers. Coefficients of variability (SD/mean x100) were similar for facial (ranges: 4.7-5.2% vs 4.9-5.6%, respectively), brachial (ranges: 5.8-8.4% vs 9.7-11.2%) and crural SFTs (ranges: 5.9-6% vs 6.2-8.7%). There was greater consistency in the measurements performed by the experienced vs the untrained worker. Inter-observer agreement, assessed through kappa statistic (k) analysis, confirmed increased measurement's agreement in the facial (k ranged from 0.40 to 0.60), brachial (k: 0.23-0.63) and crural SFT assessments (k: 0.58-0.70) from the 1(st) to 2(nd) session.
CONCLUSIONS
US shows low intra observer variability and good inter observer reliability in the assessment of body fat changes related to the HARS. The different degree of consistency by the workers and the improvement of interobserver agreement, suggest to stating a well defined period of training to obtain better US reliability.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.